• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

109-123 Floor Area Per Room Regulations

NYC Zoning Resolution > X Special Purpose Districts > 9 - Special Little Italy District (LI) > 109-10 Preservation Area (Area A) > 109-12 Bulk Regulations > 109-123 Floor Area Per Room Regulations
JUMP TO FULL CODE CHAPTER

For the purposes of this Chapter, the density requirements of Sections 23-22, 23-24 or 35-40 shall not apply to any development or enlargement. In lieu thereof, there shall be not more than one room for each 230 square feet of gross residential floor area.

Related Code Sections


502.5.2 Exhaust Systems, Ventilation Rate in Rooms
)] of floor area of the room ...
NYC Mechanical Code 2008 > 5 Exhaust Systems > 502 Required Systems > 502.5 Valve-Regulated Lead-Acid Batteries > 502.5.2 Ventilation Rate in Rooms
Article 6 Ventilation [PDF] (page 5)
be supplied an amount of fresh air equal to one cubic foot per minute per square foot of floor area and an air exhaust of one cubic foot per minute per ...
NYC 1938 Code [PDF] > 6 Ventilation
502.4 Exhaust Systems, Stationary Storage Battery Systems
per minute per square foot (cfm/ft 2 ) (0.00508 m 3 /(s • m 2 )) of floor area of the room ...
NYC Mechanical Code 2014 > 5 Exhaust Systems > 502 Required Systems > 502.4 Stationary Storage Battery Systems
305.10 General Regulations, Repair Garages
Appliances installed in repair garages shall be installed in a detached building or room, separated from repair areas by walls or partitions, floors ...
NYC Fuel Gas Code 2014 > 3 General Regulations > 305 Installation > 305.10 Repair Garages
Section 310 General Regulations, Washroom and Toilet Room Requirements
Washrooms and toilet rooms shall be illuminated and ventilated in accordance with the New York City Building Code and New York City Mechanical ...
NYC Plumbing Code 2014 > 3 General Regulations > 310 Washroom and Toilet Room Requirements
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE