417.4.1 Floor and Wall Area
JUMP TO FULL CODE CHAPTER
Bathtub floors, shower floors, wall areas above built-in tubs that have installed shower heads and walls in shower compartments shall be constructed of smooth, corrosion-resistant and nonabsorbent waterproof materials. Wall materials shall extend to a height of not less than 6 feet (1829 mm) above the room floor level, and not less than 70 inches (1778 mm) above the drain of the tub or shower. Such walls shall form a water-tight joint with each other and with either the tub or shower floor.
Related Code Sections
417.4.1 Fixtures, Faucets and Fixture Fittings, Floor and Wall Area
Bathtub floors, shower floors, wall areas above built-in tubs that have installed shower heads and walls in shower compartments shall be constructed ...
2017 FBC - Plumbing, 6th edition > 4 Fixtures, Faucets and Fixture Fittings > 417 Showers > 417.4 Shower Compartments > 417.4.1 Floor and Wall Area
421.4.1 Fixtures, Faucets and Fixture Fittings, Floor and Wall Area
Bathtub floors, shower floors, wall areas above built-in tubs that have installed shower heads and walls in shower compartments shall be constructed ...
2020 FBC - Plumbing, 7th edition > 4 Fixtures, Faucets and Fixture Fittings > 421 Showers > 421.4 Shower Compartments > 421.4.1 Floor and Wall Area
A404.1 : Guidelines for the Seismic Retrofit of Existing Buildings, Limitation
measures rely on rotation of the second floor diaphragm to distribute the seismic load between the side and rear walls of the ground floor open area. In ...
2017 FBC - Existing Building, 6th edition > A : Guidelines for the Seismic Retrofit of Existing Buildings > A404 Prescriptive Measures for Weak Story > A404.1 Limitation
A404.1 Guidelines for the Seismic Retrofit of Existing Buildings, Limitation
measures rely on rotation of the second floor diaphragm to distribute the seismic load between the side and rear walls of the ground floor open area. In ...
2014 FBC - Existing Building, 5th edition > A Guidelines for the Seismic Retrofit of Existing Buildings > A404 Prescriptive Measures for Weak Story > A404.1 Limitation
A404.1 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls, Limitation
measures rely on rotation of the second floor diaphragm to distribute the seismic load between the side and rear walls of the ground floor open area. In ...
2020 FBC - Existing Building, 7th edition > A4 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls > A404 Prescriptive Measures for Weak Story > A404.1 Limitation