• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

G105.4 Flood Shield Inspection

NYC Building Code 2014 > G Flood-Resistant Construction > G105 Progress and Special Inspection Requirements > G105.4 Flood Shield Inspection
JUMP TO FULL CODE CHAPTER
Where floodshields or other flood control devices are installed as part of a dry floodproofing system in buildings and structures that are nonresidential (for flood zone purposes), the special inspector or special inspection agency responsible for the flood zone compliance special inspection shall inspect the shields or devices in their stored positions or locations, witness their activation or transportation to their installed positions, and witness their deactivation or transportation back to their stored locations. The special inspector or special inspection agency shall also confirm the installation of signage required by ASCE 24, Section 6.2.3, Item 3.

Related Code Sections


G105.3.1 Flood-Resistant Construction, Flood Shield Inspection
that are nonresidential (for flood zone purposes), a registered design professional shall inspect the shields or devices in their stored ...
NYC Building Code 2008 > G Flood-Resistant Construction > G105 Progress and Special Inspection Requirements > G105.3 New Buildings and Substantial Improvements > G105.3.1 Flood Shield Inspection
G105.4 Flood-Resistant Construction, Flood Shield Inspection
that are nonresidential (for flood zone purposes), the special inspector or special inspection agency responsible for the flood zone compliance special inspection shall ...
NYC Building Code 2014 > G Flood-Resistant Construction > G105 Progress and Special Inspection Requirements > G105.4 Flood Shield Inspection
3202.2.2.3 Encroachments Into the Public Right-Of-Way, Flood Shield Supports
In areas of special flood hazard or shaded X-Zones, permanent attachments to building facades necessary for the support and attachment of temporary ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.2 Encroachments Not Subject to Area Limitations > 3202.2.2.3 Flood Shield Supports
3202.2.2.3 Encroachments Into the Public Right-Of-Way, Flood Shield Supports
In areas of special flood hazard or shaded X-Zones, permanent attachments to building façades necessary for the support and attachment of temporary ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.2 Encroachments Not Subject to Area Limitations > 3202.2.2.3 Flood Shield Supports
G308.6 Flood-Resistant Construction, Temporary Flood Shields
Temporary flood shields shall be permitted in accordance with Section 6.2.3 of ASCE 24 ...
NYC Building Code 2014 > G Flood-Resistant Construction > G308 Other Building Work > G308.6 Temporary Flood Shields
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE