Section 309 Flood Hazard Resistance
JUMP TO FULL CODE CHAPTER
Plumbing systems and equipment in structures erected in flood hazard areas shall be constructed in accordance with the requirements of this section and the International Building Code.
For structures located in flood hazard areas, the following systems and equipment shall be located and installed as required by Section 1612 of the International Building Code.
- Water service pipes.
- Pump seals in individual water supply systems where the pump is located below the design flood elevation.
- Covers on potable water wells shall be sealed, except where the top of the casing well or pipe sleeve is elevated to not less than 1 foot (305 mm) above the design flood elevation.
- Sanitary drainage piping.
- Storm drainage piping.
- Manhole covers shall be sealed, except where elevated to or above the design flood elevation.
- Other plumbing fixtures, faucets, fixture fittings, piping systems and equipment.
- Water heaters.
- Vents and vent systems.
Exception: The systems listed in this section are permitted to be located below the elevation required by Section 1612 of the International Building Code for utilities and attendant equipment, provided that the systems are designed and installed to prevent water from entering or accumulating within their components and the systems are constructed to resist hydrostatic and hydrodynamic loads and stresses, including the effects of buoyancy, during the occurrence of flooding up to such elevation.
Structures located in coastal high-hazard areas and coastal A zones shall meet the requirements of Section 309.2. The plumbing systems, pipes and fixtures shall not be mounted on or penetrate through walls intended to break away under flood loads.
Related Code Sections
Section 309 General Regulations, Flood Hazard Resistance
Plumbing systems and equipment in structures erected in flood hazard areas shall be constructed in accordance with the requirements of this section ...
1206.9.1 Hydronic Piping, Flood Hazard
Piping located in a flood hazard area shall be capable of resisting hydrostatic and hydrodynamic loads and stresses, including the effects ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1206 Piping Installation > 1206.9 Strains and Stresses > 1206.9.1 Flood Hazard
1210.8.6 Hydronic Piping, Flood Hazard
Piping located in a flood hazard area shall be capable of resisting hydrostatic and hydrodynamic loads and stresses, including the effects ...
Mechanical Code 2018 of Kansas > 12 Hydronic Piping > 1210 Plastic Pipe Ground-Source Heat Pump Loop Systems > 1210.8 Installation > 1210.8.6 Flood Hazard
M2105.22.1 Hydronic Piping, Flood Hazard
Piping located in a flood hazard area shall be capable of resisting hydrostatic and hydrodynamic loads and stresses, including the effects ...
Residential Code 2018 of Kansas > 21 Hydronic Piping > M2105 Ground-Source Heat-Pump System Loop Piping > M2105.22 Strains and Stresses > M2105.22.1 Flood Hazard
R322.2.1 Building Planning, Elevation Requirements
Buildings and structures in flood hazard areas, including flood hazard areas designated as Coastal A Zones, shall have the lowest floors elevated ...
Residential Code 2018 of Kansas > 3 Building Planning > R322 Flood-Resistant Construction > R322.2 Flood Hazard Areas (Including A Zones) > R322.2.1 Elevation Requirements