• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

P-809.10 Flexible Pipe

Philadelphia Plumbing Code > 8 Water Supply and Distribution > P-809 Material for Water Pipe, Tubing and Fittings > P-809.10 Flexible Pipe
JUMP TO FULL CODE CHAPTER
Polybutylene flexible pipe shall be permitted in alteration work to supply water closets and hot and cold water to a lavatory, provided the building contains not more than four dwelling units and is not over three stories in height. The basement is not considered a story height.

Related Code Sections


P-809.10 Water Supply and Distribution, Flexible Pipe
Polybutylene flexible pipe shall be permitted in alteration work to supply water closets and hot and cold water to a lavatory, provided the building ...
Philadelphia Plumbing Code > 8 Water Supply and Distribution > P-809 Material for Water Pipe, Tubing and Fittings > P-809.10 Flexible Pipe
P-602.1.3 Pipe Supports, Plastic Pipe
Flexible plastic pipe and rigid polyethylene (fuseal or similar approved drainage system) shall have continuous supports for the entire length. ABS ...
Philadelphia Plumbing Code > 6 Pipe Supports > P-602 Horizontal Piping > P-602.1 Spacing > P-602.1.3 Plastic Pipe
P-811.2.1 Water Supply and Distribution, Provisions
in pipe size to the floor or wall directly adjacent to the fixture it is intended to serve. Flexible water pipe connectors used in connecting the water ...
Philadelphia Plumbing Code > 8 Water Supply and Distribution > P-811 Water Supply Fixtures > P-811.2 Minimum Size of Fixture Supply Pipes > P-811.2.1 Provisions
5703.6.9.1 Flammable and Combustible Liquids, Fiberglass-Reinforced Plastic Piping
Fiberglass-reinforced plastic (FRP) piping is not required to be provided with flexible joints in locations where both of the following conditions ...
2018 Philadelphia Fire Code > 57 Flammable and Combustible Liquids > 5703 General Requirements > 5703.6 Piping Systems > 5703.6.9 Flexible Joints > 5703.6.9.1 Fiberglass-Reinforced Plastic Piping
1107.3 Refrigeration, Pipe Enclosures
Rigid or flexible metal enclosures or pipe ducts shall be provided for soft, annealed copper tubing and used for refrigerant piping erected ...
2018 Philadelphia Mechanical Code > 11 Refrigeration > 1107 Refrigerant Piping > 1107.3 Pipe Enclosures
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE