604.12 Flexible Corrugated Connectors
JUMP TO FULL CODE CHAPTER
Flexible corrugated connectors of copper, copper alloy, or stainless
steel shall be limited to the following connector lengths:
- Fixture Connectors - 30 inches (762 mm)
- Washing Machine Connectors - 72 inches (1829 mm)
- Dishwasher and Icemaker Connectors - 120 inches (3048 mm)
Related Code Sections
604.12 Water Supply and Distribution, Flexible Corrugated Connectors
Flexible corrugated connectors of copper, copper alloy, or stainless
steel shall be limited to the following connector lengths:
Fixture Connectors ...
California Plumbing Code 2016 > 6 Water Supply and Distribution > 604.0 Materials > 604.12 Flexible Corrugated Connectors
604.12 Water Supply and Distribution, Flexible Corrugated Connectors
Flexible corrugated connectors of copper, copper alloy, or stainless steel
shall be limited to the following connector lengths:
Fixture ...
California Plumbing Code 2019 > 6 Water Supply and Distribution > 604.0 Materials > 604.12 Flexible Corrugated Connectors
1212.4.3 Fuel Gas Piping, Flexible Connectors
Where flexible connections
are used, they shall be of the minimum practical
length and shall not extend from one room to another or
pass through ...
California Plumbing Code 2016 > 12 Fuel Gas Piping > 1212.0 Appliance Connections to Building Piping > 1212.4 Connection of Portable and Mobile Industrial Gas Appliances > 1212.4.3 Flexible Connectors
1212.5.3 Fuel Gas Piping, Flexible Connectors
Where flexible connections are used, they shall be of the minimum practical length and shall not extend from one room to another or pass through any ...
California Plumbing Code 2019 > 12 Fuel Gas Piping > 1212.0 Appliance and Equipment Connections to Building Piping > 1212.5 Connection of Portable and Mobile Industrial Gas Appliances > 1212.5.3 Flexible Connectors
1310.7.1 Health Care Facilities and Medical Gas and Medical Vacuum Systems, Flexible Connectors
Flexible connectors, metallic or nonmetallic, shall have a minimum burst pressure with a gauge pressure of 1000 psi (6895 kPa). [NFPA 99 ...
California Plumbing Code 2019 > 13 Health Care Facilities and Medical Gas and Medical Vacuum Systems > 1310.0 Installation of Piping > 1310.7 Connectors > 1310.7.1 Flexible Connectors