(A) Flexible Cords, Zones 1 and 2
Go To Full Code Chapter
A flexible cord shall be permitted for connection between portable lighting equipment or other portable utilization equipment and the fixed portion of their supply circuit. Flexible cord shall also be permitted for that portion of the circuit where the fixed wiring methods of 505.15(B) and (C) cannot provide the necessary degree of movement for fixed and mobile electrical utilization equipment in an industrial establishment where conditions of maintenance and engineering supervision ensure that only qualified persons install and service the installation, and where the flexible cord is protected by location or by a suitable guard from damage. The length of the flexible cord shall be continuous. Where flexible cords are used, the cords shall comply with the following:
- Be of a type listed for extra-hard usage.
- Contain, in addition to the conductors of the circuit, an equipment grounding conductor complying with 400.23.
- Be connected to terminals or to supply conductors in an approved manner.
- Be supported by clamps or by other suitable means in such a manner that there will be no tension on the terminal connections.
- Be terminated with a listed cord connector that maintains the type of protection where the flexible cord enters boxes, fittings, or enclosures that are required to be explosionproof or flameproof.
- Cord entering an increased safety "e" enclosure shall be terminated with a listed increased safety "e" cord connector.
Informational Note: See 400.10 for permitted uses of flexible cords.
Electric submersible pumps with means for removal without entering the wet-pit shall be considered portable utilization equipment. The extension of the flexible cord within a suitable raceway between the wet-pit and the power source shall be permitted.
Electric mixers intended for travel into and out of open-type mixing tanks or vats shall be considered portable utilization equipment.
Informational Note: See 505.18 for flexible cords exposed to liquids having a deleterious effect on the conductor insulation.
Related Code Sections
(A) Special Occupancies, Flexible Cords, Zones 1 and 2
A flexible cord shall be permitted for connection between portable lighting equipment or other portable utilization equipment and the fixed portion ...
(A) Special Occupancies, Flexible Cords, Class I, Zones 1 and 2
A flexible cord shall be permitted for connection between portable lighting equipment or other portable utilization equipment and the fixed portion ...
(2) Special Occupancies, Flexible Connections
conduit with listed fittings, liquidtight flexible nonmetallic conduit with listed fittings, or flexible cord in accordance with the provisions of 505.17 ...
506.17 Special Occupancies, Flexible Cords
Flexible cords used in Zone 20, Zone 21, and Zone 22 locations shall comply with all of the following: Be of a type listed for extra-hard usage ...
506.17 Special Occupancies, Flexible Cords
Flexible cords used in Zone 20, Zone 21, and Zone 22 locations shall comply with all of the following: Be of a type listed for extra-hard usage ...