512.2 Flat-Roofed Buildings and Structures 100 Feet or Less in Height
JUMP TO FULL CODE CHAPTER
Solar panel installations shall not obstruct any rooftop area access to which is required pursuant to FC504.4, except that solar panel installations may obstruct the clear path required by FC504.4.4 as follows:
- if the installation is provided with a hinged mechanism or other device for which a certificate of approval has been issued that enables the installation to be safely swung, slid, lifted, collapsed or otherwise moved out of the clear path, and that is designed to allow for operation by one person, without the use of a tool; or
- on any building with a rooftop width or depth of 25 feet (7620 mm) or less, where the design of a solar panel installation necessitates coverage of all or substantially all of the rooftop across the full width or length thereof, the commissioner may authorize permanent obstructions that encroach upon and thereby reduce the clear path width within such area when necessary to accommodate the presence of hatches; scuttles and skylights; bulkheads; attic ventilators; chimneys and plumbing vents; and heating, ventilation and air conditioning equipment or other rooftop building service equipment.
Related Code Sections
Article 9 Construction [PDF] (page 64)
twenty-five hundred square feet or less, shall be placed at least four feet from any lot line, and shall be covered on the sides and roof with approved ...
1609.6.1 Structural Design, Scope
as listed below: For buildings with flat, gabled or hipped roofs having a mean roof height not exceeding the least horizontal dimension or 60 feet (18 288 ...
NYC Building Code 2014 > 16 Structural Design > 1609 Wind Loads > 1609.6 Simplified Wind Load Methods > 1609.6.1 Scope
1608.3 Structural Design, Flat Roof Snow Loads
The flat roof snow load, ρ f , on a roof with a slope equal to or less than 5 degrees (0.09 rad) (1 inch per foot = 4.76 degrees) shall ...
Article 5 General Building Restrictions [PDF] (page 3)
, to exceed the limits authorized as follows: 1. For the purpose of erecting a flat roof thereon, any structure already exceeding twenty-five feet ...
1608.3 Structural Design, Flat Roof Snow Loads
The flat roof snow load, r f , on a roof with a slope equal to or less than 5 degrees (0.09 rad) (1 inch per foot = 4.76 degrees) shall ...
NYC Building Code 2008 > 16 Structural Design > 1608 Snow Loads and Thermal Loads > 1608.3 Flat Roof Snow Loads