• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.106(d)(5)(vi) Flammable Liquid Warehouses or Storage Buildings

OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(d) Container and Portable Tank Storage > 1910.106(d)(5) Storage Inside Building > 1910.106(d)(5)(vi) Flammable Liquid Warehouses or Storage Buildings
JUMP TO FULL CODE CHAPTER

1910.106(d)(5)(vi)(a)

If the storage building is located 50 feet or less from a building or line of adjoining property that may be built upon, the exposing wall shall be a blank wall having a fire-resistance rating of at least 2 hours.

1910.106(d)(5)(vi)(b)

The total quantity of liquids within a building shall not be restricted, but the arrangement of storage shall comply with Table H-14 or H-15.

1910.106(d)(5)(vi)(c)

Containers in piles shall be separated by pallets or dunnage where necessary to provide stability and to prevent excessive stress on container walls.

1910.106(d)(5)(vi)(d)

Portable tanks stored over one tier high shall be designed to nest securely, without dunnage, and adequate materials handing equipment shall be available to handle tanks safely at the upper tier level.

1910.106(d)(5)(vi)(e)

No pile shall be closer than 3 feet to the nearest beam, chord, girder, or other obstruction, and shall be 3 feet below sprinkler deflectors or discharge orifices of water spray, or other overhead fire protection systems.

1910.106(d)(5)(vi)(f)

Aisles of at least 3 feet wide shall be provided where necessary for reasons of access to doors, windows or standpipe connections.

Related Code Sections


1910.106(d)(5)(vi) Hazardous Materials, Flammable Liquid Warehouses or Storage Buildings
The total quantity of liquids within a building shall not be restricted, but the arrangement of storage shall comply with Table H-14 ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(d) Container and Portable Tank Storage > 1910.106(d)(5) Storage Inside Building > 1910.106(d)(5)(vi) Flammable Liquid Warehouses or Storage Buildings
1910.106(d)(5)(vi)(f) Hazardous Materials,
Aisles of at least 3 feet wide shall be provided where necessary for reasons of access to doors, windows or standpipe connections ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(d) Container and Portable Tank Storage > 1910.106(d)(5) Storage Inside Building > 1910.106(d)(5)(vi) Flammable Liquid Warehouses or Storage Buildings > 1910.106(d)(5)(vi)(f)
1910.106(d)(5)(v) Hazardous Materials, General Purpose Public Warehouses
creating no fire exposure hazard to the flammable liquids may be stored in the same area. TABLE H-14 - INDOOR CONTAINER STORAGE ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(d) Container and Portable Tank Storage > 1910.106(d)(5) Storage Inside Building > 1910.106(d)(5)(v) General Purpose Public Warehouses
1910.106(h)(4)(i) Hazardous Materials, Storage
The storage of flammable liquids in tanks shall be in accordance with the applicable provisions of paragraph (b) of this section ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(h) Processing Plants > 1910.106(h)(4) Liquid Handling > 1910.106(h)(4)(i) Storage
1910.106(f)(1) Hazardous Materials, Storage
flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids shall be stored in containers, or in tanks within buildings ...
OSHA 1910 General Industry > H Hazardous Materials > 1910.106 Flammable Liquids > 1910.106(f) Bulk Plants > 1910.106(f)(1) Storage
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE