• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(4) 3311.4 Flame Effects Use Plan

Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3311 Flame Effects Permit > 3311.4 Flame Effects Use Plan
JUMP TO FULL CODE CHAPTER

Before the performance of any production, the permit applicant shall submit a plan for the use of flame effects to the local fire code official. The plan shall be made in writing in such form as is acceptable to the local fire code official and shall demonstrate compliance with this rule and NFPA 160 listed in rule 1301:7-7-47 of the Administrative Code. The plan shall include but is not limited to the following:

(a) The name of the person, group, or organization sponsoring the production;

(b) The date and time of day of the production;

(c) The exact location of the production;

(d) The name of the flame effects exhibitor and proof of valid flame effects exhibitor license issued by the state fire marshal;

(e) The number, names, and ages of all assistants that will be present;

(f) The qualifications and experience of the flame effects exhibitor;

(g) The flame effects classification and design criteria in accordance with NFPA 160 listed in rule 1301:7-7-47 of the Administrative Code;

(h) A diagram of the site indicating the location of all flame effects devices, the areas effected by each device, location of the audience and separation distances, means of egress, and information on all fuels and ventilation for each effect;

(i) A narrative description of the flame effects, controls, and control sequences of all devices, and emergency response procedures;

(j) If applicable, a valid Material Safety Data Sheet (MSDS) for each fuel utilized;

(k) Documentation that the set, scenery, and rigging materials are treated with appropriate flame retardant.

After a permit has been granted, the permittee shall keep the plan available at the site for safety inspectors or other designated agents of each authority having jurisdiction.

Related Code Sections


3311.4 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Flame Effects Use Plan
Before the performance of any production, the permit applicant shall submit a plan for the use of flame effects to the local fire code official. The ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3311 Flame Effects Permit > 3311.4 Flame Effects Use Plan
3319.4.1.3 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Flame Effects Exhibitor
Any individual who applies to be examined and licensed in the classification of a flame effects exhibitor shall only be authorized to operate flame ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3319 Requirements for an Exhibitor's License > 3319.4 Application Period > 3319.4.1 New Applications > 3319.4.1.3 Flame Effects Exhibitor
520.66 Special Occupancies, Special Effects
Electrical devices used for simulating lightning, waterfalls, and the like shall be constructed and located so that flames, sparks, or hot particles ...
National Electrical Code, 2017 > 5 Special Occupancies > 520 Theaters, Audience Areas of Motion Picture and Television Studios, Performance Areas, and Similar Locations > 520.66 Special Effects
316.3 Building Planning, Surface Burning Characteristics
Unless otherwise allowed in Section 316.5 or 316.6, all foam plastic or foam plastic cores used as a component in manufactured assemblies used ...
Ohio Residential Code 2013 > 3 Building Planning > 316 Foam Plastic > 316.3 Surface Burning Characteristics
R316.3 Building Planning, Surface Burning Characteristics
Unless otherwise allowed in Section R316.5, foam plastic, or foam plastic cores used as a component in manufactured assemblies, used in building ...
2019 Residential Code of Ohio > 3 Building Planning > R316 Foam Plastic > R316.3 Surface Burning Characteristics
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE