• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1506.3.3.2 Flame Detection System

NYC Fire Code 2014 > 15 Flammable Finishes > 1506 Powder Coating > 1506.3 Design and Installation > 1506.3.3 Fire Protection > 1506.3.3.2 Flame Detection System
JUMP TO FULL CODE CHAPTER
Automated powder coating application equipment shall be protected by an approved, supervised flame detection device capable of detecting the presence of flame within 1/2 second, that shall, upon activation, automatically initiate the following actions:
  1. Shut down electrical power and compressed air supply to the powder coating operation, including the conveyor, ventilation, application, transfer and powder collection systems.
  2. Close segregation dampers in associated ductwork to interrupt airflows from application equipment to powder collectors.
  3. Activate a local alarm audible within the powder coating room or booth and surrounding area.

Related Code Sections


22.4.1.6 Special Occupancy Requirements,
the requirements in 9.8.1 of NFPA 33, the optical flame detection system shall also activate one of the following over each zone in which fire has been ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 22 Special Occupancy Requirements > 22.4 Spray Application Using Flammable or Combustible Materials > 22.4.1 Design Requirements > 22.4.1.6
3.3.2 Definitions, Damper
A device, installed in an air-distribution system, that is designed to close automatically upon detection of heat to interrupt ...
Standard for Challenge Fire Walls, Fire Walls, and Fire Barrier Walls 2015 of New York City > 3 Definitions > 3.3 General Definitions > 3.3.2 Damper
406.5 Gas Piping Installations, Detection of Leaks and Defects
of an approved gas detector, a noncorrosive leak detection fluid, or other approved leak detection methods. Matches, candles, open flames, or other methods ...
NYC Fuel Gas Code 2008 > 4 Gas Piping Installations > 406 Inspection, Testing and Purging > 406.5 Detection of Leaks and Defects
406.5 Gas Piping Installations, Detection of Leaks and Defects
of an approved gas detector, a noncorrosive leak detection fluid, or other approved leak detection methods. Matches, candles, open flames, or other methods ...
NYC Fuel Gas Code 2014 > 4 Gas Piping Installations > 406 Inspection, Testing and Purging > 406.5 Detection of Leaks and Defects
903.3.1.1.1 Fire Protection Systems, Exempt Locations Protected by Other Means
detection system in accordance with Section 907.2 that will respond to visible or invisible particles of combustion and an alternative extinguishing ...
NYC Building Code 2008 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.1 NFPA 13 Sprinkler Systems > 903.3.1.1.1 Exempt Locations Protected by Other Means
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING