709.2 Fixtures Not Listed in Table 709.1
JUMP TO FULL CODE CHAPTER
Fixtures not listed in Table 709.1 shall have a drainage fixture unit load based on the outlet size of the fixture in accordance with Table 709.2. The minimum trap size for unlisted fixtures shall be the size of the drainage outlet but not less than 11/4 inches (32 mm).
TABLE 709.2
DRAINAGE FIXTURE UNITS FOR FIXTURE DRAINS OR TRAPS
FIXTURE DRAIN OR TRAP SIZE (inches) | DRAINAGE FIXTURE UNIT VALUE |
11/4 | 1 |
11/2 | 2 |
2 | 3 |
21/2 | 4 |
3 | 5 |
4 | 6 |
For SI: 1 inch = 25.4 mm.
Related Code Sections
709.2 Sanitary Drainage, Fixtures Not Listed in Table 709.1
Fixtures not listed in Table 709.1 shall have a drainage fixture unit load based on the outlet size of the fixture in accordance with Table 709.2 ...
2014 FBC - Plumbing, 5th edition > 7 Sanitary Drainage > 709 Fixture Units > 709.2 Fixtures Not Listed in Table 709.1
709.2 Sanitary Drainage, Fixtures Not Listed in Table 709.1
Fixtures not listed in Table 709.1 shall have a drainage fixture unit load based on the outlet size of the fixture in accordance with Table 709.2 ...
2017 FBC - Plumbing, 6th edition > 7 Sanitary Drainage > 709 Fixture Units > 709.2 Fixtures Not Listed in Table 709.1
709.2 Sanitary Drainage, Fixtures Not Listed in Table 709.1
Fixtures not listed in Table 709.1 shall have a drainage fixture unit load based on the outlet size of the fixture in accordance with Table 709.2 ...
2020 FBC - Plumbing, 7th edition > 7 Sanitary Drainage > 709 Fixture Units > 709.2 Fixtures Not Listed in Table 709.1
709.1 Fire and Smoke Protection Features, General
Smoke barriers shall comply with this section ...
2014 FBC - Building, 5th edition > 7 Fire and Smoke Protection Features > 709 Smoke Barriers > 709.1 General
709.1 Fire and Smoke Protection Features, General
Vertical and horizontal smoke barriers shall comply with this section ...
2017 FBC - Building, 6th edition > 7 Fire and Smoke Protection Features > 709 Smoke Barriers > 709.1 General