Section P2722 Fixture Fitting

Residential Code 2015 of Utah > 27 Plumbing Fixtures > P2722 Fixture Fitting
JUMP TO FULL CODE CHAPTER

P2722.1 General

Fixture supply valves and faucets shall comply with ASME A112.18.1/CSA B125.1 as indicated in Table P2701.1. Faucets and fixture fittings that supply drinking water for human ingestion shall conform to the requirements of NSF 61, Section 9. Flexible water connectors shall conform to the requirements of Section P2906.7.

P2722.2 Hot Water

Fixture fittings supplied with both hot and cold water shall be installed and adjusted so that the left-hand side of the water temperature control represents the flow of hot water when facing the outlet.

Exception: Shower and tub/shower mixing valves conforming to ASSE 1016/ASME A112.1016/CSA B125.16, where the water temperature control corresponds to the markings on the device.

P2722.3 Hose-Connected Outlets

Faucets and fixture fittings with hose-connected outlets shall conform to ASME A112.18.3 or ASME A112.18.1/CSA B125.1.

P2722.4 Individual Pressure-Balancing In-Line Valves for Individual Fixture Fittings

Individual pressure-balancing in-line valves for individual fixture fittings shall comply with ASSE 1066. Such valves shall be installed in an accessible location and shall not be used as a substitute for the balanced pressure, thermostatic or combination shower valves required in Section P2708.4.

P2722.5 Water Closet Personal Hygiene Devices

Personal hygiene devices integral to water closets or water closet seats shall conform to ASME A112.4.2.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


Section P2722 Plumbing Fixtures, Fixture Fitting
Fixture supply valves and faucets shall comply with ASME A112.18.1/CSA B125.1 as indicated in Table P2701.1. Faucets and fixture fittings that supply ...
Residential Code 2015 of Utah > 27 Plumbing Fixtures > P2722 Fixture Fitting
Chapter 4 Fixtures, Faucets and Fixture Fittings
Plumbing Code 2015 of Utah > 4 Fixtures, Faucets and Fixture Fittings
Section 424 Fixtures, Faucets and Fixture Fittings, Faucets and Other Fixture Fittings
Faucets and fixture fittings shall conform to ASME A112.18.1/CSA B125.1. Faucets and fixture fittings that supply drinking water for human ingestion ...
Plumbing Code 2015 of Utah > 4 Fixtures, Faucets and Fixture Fittings > 424 Faucets and Other Fixture Fittings
424.5 Fixtures, Faucets and Fixture Fittings, Bathtub and Whirlpool Bathtub Valves
The hot water supplied to bathtubs and whirlpool bathtubs shall be limited to a maximum temperature of 120°F (49°C) by a water-temperature limiting ...
Plumbing Code 2015 of Utah > 4 Fixtures, Faucets and Fixture Fittings > 424 Faucets and Other Fixture Fittings > 424.5 Bathtub and Whirlpool Bathtub Valves
424.6 Fixtures, Faucets and Fixture Fittings, Hose-Connected Outlets
Faucets and fixture fittings with hose-connected outlets shall conform to ASME A112.18.3 or ASME A112.18.1/CSA B125.1 ...
Plumbing Code 2015 of Utah > 4 Fixtures, Faucets and Fixture Fittings > 424 Faucets and Other Fixture Fittings > 424.6 Hose-Connected Outlets
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US