914.4.2 Fixture Drain or Branch
JUMP TO FULL CODE CHAPTER
The relief vent is permitted to be a fixture drain or fixture branch for fixtures located within the same branch interval as the circuit-vented horizontal branch. The maximum discharge to a relief vent shall be four fixture units.