Section P2702 Fixture Accessories

Go To Full Code Chapter
P2702.1 Plumbing Fixtures
Plumbing fixtures, other than water closets, shall be provided with approved strainers.
Exception: Hub drains receiving only clear water waste and standpipes shall not require strainers.
P2702.2 Waste Fittings
Waste fittings shall conform to ASME A112.18.2/CSA B125.2, ASTM F409 or shall be made from pipe and pipe fittings complying with any of the standards indicated in Tables P3002.1(1) and P3002.3.
P2702.3 Plastic Tubular Fittings
Plastic tubular fittings shall conform to ASTM F409 as indicated in Table P2701.1.
P2702.4 Carriers for Wall-Hung Water Closets
Carriers for wall-hung water closets shall conform to ASME A112.6.2.