• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1808.4.3.2 Fixed Headed Piles

NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.4 Load Tests > 1808.4.3 Lateral Load Tests > 1808.4.3.2 Fixed Headed Piles
JUMP TO FULL CODE CHAPTER
For piles whose heads are designed to be fixed in the final structure, the results of the load test shall be used to verify the input parameters used in the lateral load analysis. In the absence of specific project requirements as determined by the engineer, the allowable load shall be the load that produces a gross lateral movement of 3/8 of an inch at the ground surface in the lateral load analysis.

Related Code Sections


1808.4.3.2 Soils and Foundations, Fixed Headed Piles
For piles whose heads are designed to be fixed in the final structure, the results of the load test shall be used to verify the input parameters used ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.4 Load Tests > 1808.4.3 Lateral Load Tests > 1808.4.3.2 Fixed Headed Piles
1801.3 Soils and Foundations, Definitions
section into the ground. FIXED HEADED PILE (DEEP FOUNDATION). A pile connected to a pile cap in a manner that prevents rotation of the pile head ...
NYC Building Code 2014 > 18 Soils and Foundations > 1801 General and Definitions > 1801.3 Definitions
§27-694 Foundations, Capping and Bracing of Piles
and five of subdivision (b) of this section, or by other equivalent means. The heads of the piles shall be fixed in the cap. In no event shall more than ...
NYC 1968 Code (Vol I) > 11 Foundations > 7 Pile Foundations-General Requirements > §27-694 Capping and Bracing of Piles
1808.2.9.2 Soils and Foundations, Unbraced Piles
Piles standing unbraced in air, water or in fluid soils shall be designed as columns in accordance with the provisions of this code. Such piles ...
NYC Building Code 2008 > 18 Soils and Foundations > 1808 Pier and Pile Foundations > 1808.2 Piers and Piles—General Requirements > 1808.2.9 Lateral Support > 1808.2.9.2 Unbraced Piles
1808.7.2 Soils and Foundations, Unbraced Piles
Such piles driven into firm ground can be considered fixed and laterally supported at 5 feet (1524 mm) below the ground surface and in soft material ...
NYC Building Code 2014 > 18 Soils and Foundations > 1808 Deep Foundations > 1808.7 Lateral Support > 1808.7.2 Unbraced Piles
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE