704.8.2 First Story
JUMP TO FULL CODE CHAPTER
In occupancies other than Group H, unlimited unprotected openings are permitted in the exterior walls of the first story above grade facing a street that have a fire separation distance of greater than 15 feet (4572 mm) or facing an unoccupied space. The unoccupied space shall be on the same lot or dedicated for public use, shall not be less than 30 feet (9144 mm) in width and shall have access from a street by a posted fire lane in accordance with the Fire Code of New York State .
Related Code Sections
704.8.2 Fire-Resistance-Rated Construction, First Story
In occupancies other than Group H, unlimited unprotected openings are permitted in the exterior walls of the first story above grade facing a street ...
2010 Building Code of NY > 7 Fire-Resistance-Rated Construction > 704 Exterior Walls > 704.8 Allowable Area of Openings > 704.8.2 First Story
509.8 General Building Heights and Areas, Group B or M With Group S-2 Open Parking Garage Above
Group B or M uses located in the basement or first story below a Group S-2 open parking garage shall be classified as a separate and distinct ...
2010 Building Code of NY > 5 General Building Heights and Areas > 509 Special Provisions > 509.8 Group B or M With Group S-2 Open Parking Garage Above
2308.6.10.1 Wood, Limitations of Concrete or Masonry Veneer in Seismic Design Category B or C
:
In structures assigned to Seismic Design Category B, stone and masonry veneer is permitted to be used in the first two stories above grade ...
Building Code 2015 of New York State > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.6 Wall Bracing > 2308.6.10 Limitations of Concrete or Masonry Veneer > 2308.6.10.1 Limitations of Concrete or Masonry Veneer in Seismic Design Category B or C
2308.6.10 Wood, Limitations of Concrete or Masonry Veneer
stories above grade plane or the first three stories above grade plane where the lowest story has concrete or masonry walls, provided that wood ...
2020 Building Code of New York State > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.6 Wall Bracing > 2308.6.10 Limitations of Concrete or Masonry Veneer
2308.11.2 Wood, Concrete or Masonry
in the first two stories above grade plane or the first three stories above grade plane where the lowest story has concrete or masonry walls in Seismic ...
2010 Building Code of NY > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.11 Additional Requirements for Conventional Construction in Seismic Design Category B or C > 2308.11.2 Concrete or Masonry