All fireworks and pyrotechnic devices shall be stored and maintained in compliance with the provisions of the Revised Code, paragraphs (T)(1)(3320.1) and (U)(3321) of this rule and in accordance with the provisions of NFPA 1124 as listed in rule 1301:7-7-47 of the Administrative Code. To the extent not addressed by the Revised Code, paragraphs (T)(1)(3320.1) and (U)(3321) of this rule and NFPA 1124 as listed in rule 1301:7-7-47 of the Administrative Code, fireworks storage must also be in accordance with paragraph (D)(3304) of this rule. All licensed manufacturer and wholesalers shall store fireworks only on the licensed premises or on an approved storage location that is part of a licensed premises.
"1.3G" fireworks, black powder, and other raw bulk explosive materials shall be stored in magazines in accordance with the provisions of this rule.
Fireworks may be stored in trailers if the trailers are properly enclosed, secured, placarded, and grounded and are separated from any structure to which the public is admitted by a distance that will allow fire-fighting equipment to have full access to the structures on the licensed premises in accordance with rule 1301:7-7-05 of the Administrative Code or as approved in writing by the local fire code official. In no instance shall trailers used for the storage of fireworks be located at a distance less than the minimum separation distances specified in NFPA 1124 as listed in rule 1301:7-7-47 of the Administrative Code. Such trailers may be moved into closer proximity to any structure only to accept or discharge cargo for a period not to exceed forty-eight hours. Only two such trailers may be placed in such closer proximity at any one time. At no time may trailers be used for conducting sales of any class of fireworks. Members of the public shall be prohibited from access to the contents of any storage trailers at all times. Trailers and magazines used for the storage of fireworks shall be completely enclosed with an approved steel chain link fence or similar barrier at least 6 feet high. The state fire marshal shall approve the installation and location of such fences or similar barriers. The installation and location of such fences or similar barriers shall properly maintain the required fire department access and properly prohibit unauthorized public access. Such fences or similar barriers shall be separated from all storage trailers and magazines containing fireworks by at least 10 feet and shall have a gate that is locked and secured against unauthorized entry.
The storage of any 1.3G fireworks in semi-trailers is limited to the normal loading and unloading of shipments of fireworks that have been shipped in accordance with DOTn regulations.
Exception: Semi-trailers which have been converted to a magazine approved for the storage of explosive materials.
Fireworks may be stored in trailers at approved storage locations only in accordance with the provisions of sections 3743.04 (J) and 3743.17 (H) of the Revised Code and this rule.
Related Code Sections
Section 3321 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Fireworks Storage
of the Administrative Code, fireworks storage must also be in accordance with paragraph (D)(3304) of this rule. All licensed manufacturer and wholesalers shall ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3321 Fireworks Storage
3308.7.1.6 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks,
The manner and place of storage of all fireworks prior to and during the fireworks exhibition for all fireworks storage shall be in accordance ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3308 Fireworks Exhibition > 3308.7 > 3308.7.1 > 3308.7.1.6
3310.1 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Storage
The storage of fireworks at the exhibition site shall comply with the requirements of this paragraph and NFPA 1123 and NFPA 1126 as listed in rule ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3310 Storage of Fireworks at Exhibition Site > 3310.1 Storage
3310.3 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Weather Protection
Fireworks shall be kept dry after delivery to the exhibition site ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3310 Storage of Fireworks at Exhibition Site > 3310.3 Weather Protection
3310.5 Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks, Sorting and Separation
After delivery to the exhibition site and prior to the fireworks exhibition, all aerial shells shall be separated according to size ...
Ohio Fire Code 2011 > Ohio Administrative Code 1301:7-7-33 Explosives and Fireworks > 3310 Storage of Fireworks at Exhibition Site > 3310.5 Sorting and Separation