• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

410.3.5.2 Fire Test

2010 Building Code of NY > 4 Special Detailed Requirements Based on Use and Occupancy > 410 Stages and Platforms > 410.3 Stages > 410.3.5 Proscenium Curtain > 410.3.5.2 Fire Test
JUMP TO FULL CODE CHAPTER
A sample curtain with a minimum of two vertical seams shall be subjected to the standard fire test specified in ASTM E 119 for a period of 30 minutes. The curtain shall overlap the furnace edges by an amount that is appropriate to seal the top and sides. The curtain shall have a bottom pocket containing a minimum of 4 pounds per linear foot (5.9 kg/m) of batten. The exposed surface of the curtain shall not glow, and flame or smoke shall not penetrate the curtain during the test period. Unexposed surface temperature and hose stream test requirements are not applicable to the proscenium fire safety curtain test.

Related Code Sections


1509.2 Roof Assemblies and Rooftop Structures, Fire Testing
Radiant barriers shall be permitted for use above decks where the radiant barrier is covered with an approved roof covering and the system ...
Building Code 2015 of New York State > 15 Roof Assemblies and Rooftop Structures > 1509 Radiant Barriers Installed Above Deck > 1509.2 Fire Testing
1509.2 Roof Assemblies and Rooftop Structures, Fire Testing
Radiant barriers shall be permitted for use above decks where the radiant barrier is covered with an approved roof covering and the system ...
2020 Building Code of New York State > 15 Roof Assemblies and Rooftop Structures > 1509 Radiant Barriers Installed Above Deck > 1509.2 Fire Testing
410.3.5.2 Special Detailed Requirements Based on Use and Occupancy, Fire Test
A sample curtain with a minimum of two vertical seams shall be subjected to the standard fire test specified in ASTM E 119 for a period of 30 minutes ...
2010 Building Code of NY > 4 Special Detailed Requirements Based on Use and Occupancy > 410 Stages and Platforms > 410.3 Stages > 410.3.5 Proscenium Curtain > 410.3.5.2 Fire Test
713.3 Fire-Resistance-Rated Construction, Fire Test Criteria
Fire-resistant joint systems shall be tested in accordance with the requirements of either ASTM E 1966 or UL 2079. Nonsymmetrical wall joint systems ...
2010 Building Code of NY > 7 Fire-Resistance-Rated Construction > 713 Fire-Resistant Joint Systems > 713.3 Fire Test Criteria
715.3 Fire and Smoke Protection Features, Fire Test Criteria
Fire-resistant joint systems shall be tested in accordance with the requirements of either ASTM E1966 or UL 2079. Nonsymmetrical wall joint systems ...
2020 Building Code of New York State > 7 Fire and Smoke Protection Features > 715 Fire-Resistant Joint Systems > 715.3 Fire Test Criteria
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE