• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

A-902.2.6 Fire Suppression Equipment

Philadelphia Administrative Code > 9 Fees > A-902 Building, Fuel Gas and Mechanical Code Fees > A-902.2 Construction > A-902.2.6 Fire Suppression Equipment
JUMP TO FULL CODE CHAPTER
For the installation or alteration of fire suppression systems, the fee shall be as follows, except that the minimum fee shall be $150:

Exception: For the installation of a complete fire sprinkler system within a one- or two-family dwelling the fee shall be $150.

    For each sprinkler head or suppression nozzle . . . . . $12

    For the installation of a backflow prevention device on a fire suppression system (where presented as a separate permit) . . . . . $125

    For each standpipe riser (per floor) . . . . . $60

    For each yard hydrant . . . . . $60

    For each fire pump . . . . . $275

    For commercial cooking extinguishing systems (each) . . . . . $125


UpCodes note: Section A-902.2.6 was amended, Bill No. 070821 (approved November 15, 2007).

A-902.2.6.1 Minor Alterations

Fees for minor alterations to fire suppression systems shall be as listed below:

Exception: The fee for a one- or two-family dwelling shall be $55.

For relocation of fire sprinklers:

20 sprinklers or less . . . . . $60

More than 20 sprinklers . . . . . $60 plus $4 per each additional sprinkler above 20

UpCodes note: Section A-902.2.6.1 was amended by Bill No. 080165 (approved June 18, 2008).

Related Code Sections


A-902.2.6 Fees, Fire Suppression Equipment
For the installation or alteration of fire suppression systems, the fee shall be as follows, except that the minimum fee shall be $150 ...
Philadelphia Administrative Code > 9 Fees > A-902 Building, Fuel Gas and Mechanical Code Fees > A-902.2 Construction > A-902.2.6 Fire Suppression Equipment
2903.3 Manufacture of Organic Coatings, Fire-Fighting Access
control. Approved aisles shall be maintained for the unobstructed movement of personnel and fire suppression equipment ...
2018 Philadelphia Fire Code > 29 Manufacture of Organic Coatings > 2903 General Precautions > 2903.3 Fire-Fighting Access
403.8.3.1 Emergency Planning and Preparedness, Employee Training
Employees shall be instructed in the proper use of portable fire extinguishers and other manual fire suppression equipment. Training of new employees ...
2018 Philadelphia Fire Code > 4 Emergency Planning and Preparedness > 403 Emergency Preparedness Requirements > 403.8 Group I Occupancies > 403.8.3 Group I-3 Occupancies > 403.8.3.1 Employee Training
914.2 Fire Protection and Life Safety Systems, Equipment Room Identification
Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers ...
2018 Philadelphia Building Code > 9 Fire Protection and Life Safety Systems > 914 Emergency Responder Safety Features > 914.2 Equipment Room Identification
510.7.3 Exhaust Systems, Wall Assemblies
the point of penetration to the outlet terminal, except where the interior of the duct is equipped with an approved automatic fire suppression system ...
2018 Philadelphia Mechanical Code > 5 Exhaust Systems > 510 Hazardous Exhaust Systems > 510.7 Penetrations > 510.7.3 Wall Assemblies
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE