Fire-retardant-treated wood shakes and shingles shall be treated by impregnation with chemicals by the full-cell vacuum-pressure process, in accordance with AWPA C1. Each bundle shall be marked to identify the manufactured unit and the manufacturer, and shall be labeled to identify the classification of the material in accordance with the testing required in Section R902.1, the treating company and the quality control agency.

Related Code Sections

R902.2 Roof Assemblies, Fire-Retardant-Treated Shingles and Shakes
Fire-retardant-treated wood shakes and shingles shall be treated by impregnation with chemicals by the full-cell vacuum-pressure process ...
R905.8.5 Roof Assemblies, Material Standards
and Shingle Bureau Fire-retardant-treated shakes and shingles of naturally durable wood 1 Cedar Shake and Shingle Bureau Preservative ...