Section 3406 Fire Escapes
JUMP TO FULL CODE CHAPTER
Fire escapes shall not constitute any part of the required means of egress in new buildings.
Existing fire escapes shall be continued to be accepted as a component in the means of egress in existing buildings only.
Where located on the front of the building and where projecting beyond the building line, the lowest landing shall not be less than 7 feet (2134 mm) or more than 12 feet (3658 mm) above grade, and shall be equipped with a counterbalanced stairway to the street. In alleyways and thoroughfares less than 30 feet (9144 mm) wide, the clearance under the lowest landing shall not be less than 12 feet (3658 mm).
The fire escape shall be designed to support a live load of 100 pounds per square foot (4788 Pa) and shall be constructed of steel or other approved noncombustible materials. Fire escapes constructed of wood not less than nominal 2 inches (51 mm) thick are permitted on buildings of Type V construction. Walkways and railings located over or supported by combustible roofs in buildings of Type III and IV construction are permitted to be of wood not less than nominal 2 inches (51 mm) thick.
Doors and windows along the fire escape shall be protected with 3/4-hour opening protectives.
Related Code Sections
Section 3406 Existing Buildings and Structures, Fire Escapes
Fire escapes shall be permitted only as provided for in Sections 3406.1.1 through 3406.1.4 ...
Section 405 Prescriptive Compliance Method, Fire Escapes
Fire escapes shall be permitted only as provided for in Sections 405.1.1 through 405.1.4 ...
Section 504 Prescriptive Compliance Method, Fire Escapes
Fire escapes shall be permitted only as provided for in Sections 504.1.1 through 504.1.4 ...
1104.16 Construction Requirements for Existing Buildings, Fire Escape Stairways
Fire escape stairways shall comply with Sections 1104.16.1 through 1104.16.7 ...
Fire Code 2018 of South Holland > 11 Construction Requirements for Existing Buildings > 1104 Means of Egress for Existing Buildings > 1104.16 Fire Escape Stairways
1104.16 Construction Requirements for Existing Buildings, Fire Escape Stairs
Fire escape stairs shall comply with Sections 1104.16.1 through 1104.16.7 ...
Fire Code 2012 of South Holland > 11 Construction Requirements for Existing Buildings > 1104 Means of Egress for Existing Buildings > 1104.16 Fire Escape Stairs