§1025-01 Fire Escape Window Gates and Similar Security Devices for Secondary Means of Egress and Emergency Escape and Rescue Openings

Title 3 ‒ Fire Department > 10 Means of Egress > §1025-01 Fire Escape Window Gates and Similar Security Devices for Secondary Means of Egress and Emergency Escape and Rescue Openings
JUMP TO FULL CODE CHAPTER
   (a)   Scope. This section sets forth standards, requirements and procedures for the design, installation, operation and maintenance of gates, bars, grilles, grates or similar devices placed over:
      (1)   windows and other openings onto fire escapes, as set forth in FC1025 and New York State Multiple Dwelling Law § 53(1)(c);
      (2)   other required secondary means of egress in multiple dwellings, as set forth in New York State Multiple Dwelling Law § 53(1)(c); and
      (3)   emergency escape and rescue openings, as set forth in FC1025.
   (b)   Definitions. The following term shall, for purposes of this section and as used elsewhere in the rules, have the meaning shown herein:
Window/egress gate. Any gate, bar, grille, grate or similar device placed over any window or other opening onto a fire escape, any required secondary means of egress in a multiple dwelling, or any emergency escape and rescue opening.
   (c)   General Provisions.
      (1)   Compliance with provisions of law. All window/egress gates shall be designed, installed and maintained in compliance with the requirements of FC Chapter 10, the Building Code and the New York State Multiple Dwelling Law.
      (2)   Certificate of approval required. All window/egress gates shall be of a type for which a certificate of approval has been issued.
   (d)   Design and Installation Requirements. Window/egress gates shall be designed installed in a manner that:
      (1)   does not reduce the required dimensions of the window or other opening;
      (2)   does not prevent or impede the proper operation or free movement of the window or other opening;
      (3)   is without projections that can snag the clothing of those escaping through the opening;
      (4)   does not swing up to open;
      (5)   is readily openable from the inside of the building or structure with no more than one releasing operation, and without the use of a tool, key or special knowledge or effort;
      (6)   will readily open manually even if springs or other automatic actuating devices used to assist in the release operation do not operate properly or at all;
      (7)   unlatches upon the application of the following force:
            (A)   For finger-actuated or hand-actuated system, a force of not more than five (5) pounds.
            (B)   For foot-actuated systems, a force of not more than 15 pounds.
            (C)   For foot-actuated systems designed to be operated by a kick, a force of not more than the impact of swinging a 25-pound weight on a four-foot pendulum over a horizontal distance of ten (10) inches;
      (8)   once unlatched, opens upon the application of the following force:
            (A)   To set the window/egress gate in motion, a force of not more than 30 pounds.
            (B)   To open the window/egress gate to the minimum width of the opening, a force of not more than 15 pounds;
      (9)   attaches to the jamb of the window or other opening with standard wood or sheet metal screws only. No other fastening devices shall be used. The depth of the actual screw anchorage shall be no more than one (1) inch; and
      (10)   leaves one-quarter (1/4) of an inch continuous space with a depth of at least three- quarters (3/4) of an inch between the window/egress gate and the frame of the window or other opening for the entire height of the window/egress gate.
   (e)   Operational and Maintenance Requirements. Window/egress gates shall be operated and maintained in compliance with the following requirements:
      (1)   Window/egress gates shall not be obstructed in a manner that would prevent or impede access to, or the proper operation or free movement of, such device.
      (2)   Window/egress gates shall be maintained in good working order. They shall be checked for proper operation at least once every six (6) months.
      (3)   Window/egress gates shall be permanently marked, labeled or tagged with the certificate of approval number and the name, address and telephone number of the manufacturer.
      (4)   The manufacturer of the window/egress gate shall provide printed installation and operating instructions with each such device. Such instructions shall set forth how to install and initially test the window/egress gate, how to operate the window/egress gate in order to exit through the window or other opening, and any required periodic testing and maintenance. When the window/egress gate is installed by a person other than an occupant of the dwelling unit or other space in which such device is installed, or other end user, the installer shall provide a copy of such instructions to such occupant or other end user.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


§1025-01 Means of Egress, Fire Escape Window Gates and Similar Security Devices for Secondary Means of Egress and Emergency Escape and Rescue Openings
: Window/egress gate. Any gate, bar, grille, grate or similar device placed over any window or other opening onto a fire escape, any required ...
Title 3 ‒ Fire Department > 10 Means of Egress > §1025-01 Fire Escape Window Gates and Similar Security Devices for Secondary Means of Egress and Emergency Escape and Rescue Openings
Section 1025 Means of Egress, Emergency Escape and Rescue
placed over emergency escape and rescue openings, and windows or other openings onto fire escapes, shall be of a type for which a certificate ...
NYC Fire Code 2014 > 10 Means of Egress > 1025 Emergency Escape and Rescue
1027.6.2 Means of Egress, Window Gates
Bars, grilles, grates or similar devices placed over windows or other openings onto fire escapes shall be maintained in good working order ...
NYC Fire Code 2014 > 10 Means of Egress > 1027 Maintenance of the Means of Egress > 1027.6 Fire Escapes > 1027.6.2 Window Gates
Section 1029 Means of Egress, Emergency Escape and Rescue
An emergency escape and rescue opening with a finished sill height below the adjacent ground level shall be provided with a window well in accordance ...
NYC Building Code 2014 > 10 Means of Egress > 1029 Emergency Escape and Rescue
Section 1025 Means of Egress, Emergency Escape and Rescue
inches (914 mm). The area of the window well shall allow the emergency escape and rescue opening to be fully opened ...
NYC Building Code 2008 > 10 Means of Egress > 1025 Emergency Escape and Rescue
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US