• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.152(d) Fire Control for Flammable Liquid Storage

OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(d) Fire Control for Flammable Liquid Storage
JUMP TO FULL CODE CHAPTER

1926.152(d)(1)

At least one portable fire extinguisher, having a rating of not less than 20-B units, shall be located outside of, but not more than 10 feet from, the door opening into any room used for storage of more than 60 gallons of flammable liquids.

1926.152(d)(2)

At least one portable fire extinguisher having a rating of not less than 20-B units shall be located not less than 25 feet, nor more than 75 feet, from any flammable liquid storage area located outside.

1926.152(d)(3)

When sprinklers are provided, they shall be installed in accordance with the Standard for the Installation of Sprinkler Systems, NFPA 13-1969.

1926.152(d)(4)

At least one portable fire extinguisher having a rating of not less than 20-B:C units shall be provided on all tank trucks or other vehicles used for transporting and/or dispensing flammable liquids.

Related Code Sections


1926.152(d) Fire Protection and Prevention, Fire Control for Flammable Liquid Storage
, the door opening into any room used for storage of more than 60 gallons of flammable liquids ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(d) Fire Control for Flammable Liquid Storage
1926.152 Fire Protection and Prevention, Flammable Liquids
Only approved containers and portable tanks shall be used for storage and handling of flammable liquids. Approved safety cans or Department ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids
1926.152(b) Fire Protection and Prevention, Indoor Storage of Flammable Liquids
No more than 25 gallons of flammable liquids shall be stored in a room outside of an approved storage cabinet. For storage of liquefied petroleum gas ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(b) Indoor Storage of Flammable Liquids
1926.152(b)(4) Fire Protection and Prevention,
Materials which will react with water and create a fire hazard shall not be stored in the same room with flammable liquids ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(b) Indoor Storage of Flammable Liquids > 1926.152(b)(4)
1926.152(i) Fire Protection and Prevention, Tank Storage
shall not be used for the storage of a flammable liquid at a temperature at or above its boiling point ...
OSHA 1926 Construction > F Fire Protection and Prevention > 1926.152 Flammable Liquids > 1926.152(i) Tank Storage
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE