• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

707.3.10 Fire Areas

Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 707 Fire Barriers > 707.3 Fire-Resistance Rating > 707.3.10 Fire Areas
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
The fire barriers, fire walls or horizontal assemblies, or combination thereof, separating a single occupancy into different fire areas shall have a fire-resistance rating of not less than that indicated in Table 707.3.10. The fire barriers, fire walls or horizontal assemblies, or combination thereof, separating fire areas of mixed occupancies shall have a fire-resistance rating of not less than the highest value indicated in Table 707.3.10 for the occupancies under consideration.

TABLE 707.3.10
FIRE-RESISTANCE RATING REQUIREMENTS FOR
FIRE BARRIERS, FIRE WALLS OR HORIZONTAL
ASSEMBLIES BETWEEN FIRE AREAS
OCCUPANCY GROUP FIRE-RESISTANCE RATING
(hours)
H-1, H-2 4
F-1, H-3, S-1 3
A, B, E, F-2, H-4, H-5, I, M, R, S-2 2
U 1

Related Code Sections


707.3.10 Fire and Smoke Protection Features, Fire Areas
The fire barriers , fire walls or horizontal assemblies , or combination thereof, separating a single occupancy into different fire areas shall ...
Building Code 2018 of Illinois > 7 Fire and Smoke Protection Features > 707 Fire Barriers > 707.3 Fire-Resistance Rating > 707.3.10 Fire Areas
707.3.10 Fire and Smoke Protection Features, Fire Areas
areas shall have a fire-resistance rating of not less than that indicated in Table 707.3.10. The fire barriers , fire walls, horizontal ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 707 Fire Barriers > 707.3 Fire-Resistance Rating > 707.3.10 Fire Areas
901.7 Fire Protection and Life Safety Systems, Fire Areas
Where buildings, or portions thereof, are divided into fire areas so as not to exceed the limits established for requiring a fire protection ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 901 General > 901.7 Fire Areas
901.7 Fire Protection and Life Safety Systems, Fire Areas
Where buildings, or portions thereof, are divided into fire areas so as not to exceed the limits established for requiring a fire protection system ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 901 General > 901.7 Fire Areas
711.2.4.2 Fire and Smoke Protection Features, Separating Fire Areas
Where the horizontal assembly separates a single occupancy into different fire areas , the assembly shall have a fire-resistance rating ...
Building Code 2021 of Illinois > 7 Fire and Smoke Protection Features > 711 Floor and Roof Assemblies > 711.2 Horizontal Assemblies > 711.2.4 Fire-Resistance Rating > 711.2.4.2 Separating Fire Areas
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING