507.4.3.1 Fire
JUMP TO FULL CODE CHAPTER
In the event of a fire within a
kitchen exhaust system, the duct and its enclosure
(rated shaft, factory-built grease duct enclosure, or
field-applied grease duct enclosure) shall be
inspected by qualified personnel to determine
whether the duct and protection method are structurally
sound, capable of maintaining their fire protection
function, and in accordance with this chapter
for continued operation. [NFPA 96:4.2.4.2]
Related Code Sections
507.3.3.1 Exhaust Systems, Fire
In the event of a fire within a kitchen
exhaust system, the duct and its enclosure (rated
shaft, factory-built grease duct enclosure, or field ...
California Mechanical Code 2016 > 5 Exhaust Systems > 507.0 General Requirements > 507.3 Clearance > 507.3.3 Clearance Integrity > 507.3.3.1 Fire
507.4.3.1 Exhaust Systems, Fire
In the event of a fire within a
kitchen exhaust system, the duct and its enclosure
(rated shaft, factory-built grease duct enclosure, or
field ...
California Mechanical Code 2019 > 5 Exhaust Systems > 507.0 General Requirements > 507.4 Clearance > 507.4.3 Clearance Integrity > 507.4.3.1 Fire
703.1.3 Fire and Smoke Protection Features, Fire Walls, Fire Barriers and Fire Partitions
Required fire walls, fire barriers and fire partitions shall be maintained to prevent the passage of fire. Openings protected with approved doors ...
California Fire Code 2016 > 7 Fire and Smoke Protection Features > 703 Fire-Resistance-Rated Construction > 703.1 Maintenance > 703.1.3 Fire Walls, Fire Barriers and Fire Partitions
4811.12 Motion Picture and Television Production Studio Sound Stages, Approved Production Facilities and Production Locations, Fire Hydrants and Fire Appliances
Hydrants, standpipes and fire department connections (FDC) shall not be obstructed, blocked or rendered inoperable in accordance with Chapter 9 ...
California Fire Code 2016 > 48 Motion Picture and Television Production Studio Sound Stages, Approved Production Facilities and Production Locations > 4811 Production Locations > 4811.12 Fire Hydrants and Fire Appliances
4811.12 Motion Picture and Television Production Studio Sound Stages, Approved Production Facilities and Production Locations, Fire Hydrants and Fire Appliances
Hydrants, standpipes and fire department connections (FDC) shall not be obstructed, blocked or rendered inoperable in accordance with Chapter 9 ...
California Fire Code 2019 > 48 Motion Picture and Television Production Studio Sound Stages, Approved Production Facilities and Production Locations > 4811 Production Locations > 4811.12 Fire Hydrants and Fire Appliances