• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1405.2.2 Final Piping Inspection

California Mechanical Code 2019 > 14 Process Piping > 1405.0 Inspections > 1405.2 Required Inspections > 1405.2.2 Final Piping Inspection
JUMP TO FULL CODE CHAPTER
This inspection shall be made after piping authorized by the permit has been installed and after portions thereof that are to be covered or concealed are so concealed. This inspection shall include a pressure test, at which time the piping shall stand a pressure of not less than one-and-one-half times the maximum designed operating pressure where hydraulic testing is conducted or 110 percent where testing is conducted pneumatically. Test pressures shall be held for a length of time satisfactory to the Authority Having Jurisdiction, but in no case for less than 30 minutes with no perceptible drop in pressure. HPM drain, waste, and vent piping shall be tested in accordance with the plumbing code. Tests shall be made in the presence of the Authority Having Jurisdiction. Necessary apparatus for conducting tests shall be furnished by the permit holder.

Related Code Sections


1203.3.2 Fuel Gas Piping, Final Piping Inspection
This inspection shall be made after piping authorized by the permit has been installed and after portions thereof that are to be covered or concealed ...
California Plumbing Code 2016 > 12 Fuel Gas Piping > 1203.0 Inspection > 1203.3 Type of Inspections > 1203.3.2 Final Piping Inspection
1203.3.2 Fuel Gas Piping, Final Piping Inspection
This inspection shall be made after piping authorized by the permit has been installed, and after portions, thereof that are to be covered ...
California Plumbing Code 2019 > 12 Fuel Gas Piping > 1203.0 Inspection > 1203.3 Type of Inspections > 1203.3.2 Final Piping Inspection
1303.3.2 Fuel Gas Piping, Final Piping Inspection
This inspection shall be made after piping authorized by the permit has been installed and after portions thereof that are to be covered or concealed ...
California Mechanical Code 2016 > 13 Fuel Gas Piping > 1303.0 Inspection > 1303.3 Type of Inspections > 1303.3.2 Final Piping Inspection
1303.3.2 Fuel Gas Piping, Final Piping Inspection
This inspection shall be made after piping authorized by the permit has been installed and after portions thereof that are to be covered or concealed ...
California Mechanical Code 2019 > 13 Fuel Gas Piping > 1303.0 Inspection > 1303.3 Type of Inspections > 1303.3.2 Final Piping Inspection
1405.2.2 Process Piping, Final Piping Inspection
This inspection shall be made after piping authorized by the permit has been installed and after portions thereof that are to be covered or concealed ...
California Mechanical Code 2016 > 14 Process Piping > 1405.0 Inspections > 1405.2 Required Inspections > 1405.2.2 Final Piping Inspection
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE