454.1.8.8 Filtration Recirculation
JUMP TO FULL CODE CHAPTER
Spa-type pools shall have a minimum of one turnover every 30 minutes. The piping, fittings, and hydraulic requirements shall be in accordance with Section 454.1.6.5. All recirculation lines to and from the pool shall be individually valved with proportional flow-type valves in order to control the recirculation flow.
Related Code Sections
454.1.8.8 Special Detailed Requirements Based on Use and Occupancy, Filtration Recirculation
with Section 454.1.6.5. All recirculation lines to and from the pool shall be individually valved with proportional flow-type valves in order to control ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 454 Swimming Pools and Bathing Places (Public and Private) > 454.1 Public Swimming Pools and Bathing Places > 454.1.8 Spa Pools > 454.1.8.8 Filtration Recirculation
454.1.8.8 Special Detailed Requirements Based on Use and Occupancy, Filtration Recirculation
with Section 454.1.6.5. All recirculation lines to and from the pool shall be individually valved with proportional flow-type valves in order to control ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 454 Swimming Pools and Bathing Places (Public and Private) > 454.1 Public Swimming Pools and Bathing Places > 454.1.8 Spa Pools > 454.1.8.8 Filtration Recirculation
454.1.8.8 Special Detailed Requirements Based on Occupancy and Use, Filtration Recirculation
with Section 454.1.6.5. All recirculation lines to and from the pool shall be individually valved with proportional flow-type valves in order to control ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 454 Swimming Pools and Bathing Places (Public and Private) > 454.1 Public Swimming Pools and Bathing Places > 454.1.8 Spa Pools > 454.1.8.8 Filtration Recirculation
454.1.9.2.6.1 Special Detailed Requirements Based on Occupancy and Use, Recirculation Rate
The recirculation-filtration system of water slides shall recirculate and filter a water volume equal to the total water volume of the facility ...
2020 FBC - Building, 7th edition > 4 Special Detailed Requirements Based on Occupancy and Use > 454 Swimming Pools and Bathing Places (Public and Private) > 454.1 Public Swimming Pools and Bathing Places > 454.1.9 Water Recreation Attractions and Specialized Pools > 454.1.9.2 Water Slides > 454.1.9.2.6 Water Slide Recirculation—filtration Equipment > 454.1.9.2.6.1 Recirculation Rate
454.1.6.5.16.1.2 Special Detailed Requirements Based on Use and Occupancy,
When booster pumps are used with the chlorinator, the pump shall use recirculated pool water supplied via the recirculation filtration system. The ...
2017 FBC - Building, 6th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 454 Swimming Pools and Bathing Places (Public and Private) > 454.1 Public Swimming Pools and Bathing Places > 454.1.6 Plumbing Systems > 454.1.6.5 Recirculation and Treatment Systems > 454.1.6.5.16 Addition of Chemicals > 454.1.6.5.16.1 Gas Chlorination > 454.1.6.5.16.1.2