P2902.4.1 Fill Valves
JUMP TO FULL CODE CHAPTER
Flush tanks shall be equipped with an antisiphon fill valve conforming to ASSE 1002/ASME A112.1002/CSA B125.12 or CSA B125.3. The critical level of the fill valve shall be located not less than 1 inch (25 mm) above the top of the flush tank overflow pipe.
Related Code Sections
415.3.1 Fixtures, Faucets and Fixture Fittings, Fill Valves
Flush tanks shall be equipped with an antisiphon fill valve conforming to ASSE 1002/ASME A112.1002/CSA B125.12 or CSA B125.3. The fill valve backflow ...
Plumbing Code 2018 of Kansas > 4 Fixtures, Faucets and Fixture Fittings > 415 Flushing Devices for Water Closets and Urinals > 415.3 Flush Tanks > 415.3.1 Fill Valves
P2902.4.1 Water Supply and Distribution, Fill Valves
Flush tanks shall be equipped with an antisiphon fill valve conforming to ASSE 1002/ASME A112.1002/CSA B125.12 or CSA B125.3. The critical level ...
Residential Code 2018 of Kansas > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.4 Protection of Potable Water Outlets > P2902.4.1 Fill Valves
1402.8.6.2 Solar Thermal Systems, Drain and Fill Valve Caps
Drain caps shall be installed on drain and fill valves ...
Mechanical Code 2018 of Kansas > 14 Solar Thermal Systems > 1402 Design and Installation > 1402.8 Equipment > 1402.8.6 Solar Loop > 1402.8.6.2 Drain and Fill Valve Caps
M2301.2.11.2 Solar Thermal Energy Systems, Drain and Fill Valve Labels and Caps
Drain and fill valves shall be labeled with a description and warning that identifies the fluid in the solar loop and a warning that the fluid might ...
Residential Code 2018 of Kansas > 23 Solar Thermal Energy Systems > M2301 Solar Thermal Energy Systems > M2301.2 Design and Installation > M2301.2.11 Solar Loop > M2301.2.11.2 Drain and Fill Valve Labels and Caps
606.5.6 Water Supply and Distribution, Potable Water Inlet Control and Location
Potable water inlets to gravity tanks shall be controlled by a fill valve or other automatic supply valve installed so as to prevent the tank from ...
Plumbing Code 2018 of Kansas > 6 Water Supply and Distribution > 606 Installation of the Building Water Distribution System > 606.5 Water Pressure Booster Systems > 606.5.6 Potable Water Inlet Control and Location