• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R804.2.5 Fastening Requirements

Los Angeles Residential Code > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.2 Structural Framing > R804.2.5 Fastening Requirements
JUMP TO FULL CODE CHAPTER
Screws for steel-to-steel connections shall be installed with a minimum edge distance and center-to-center spacing of 1/2 inch (12.7 mm), shall be self-drilling tapping and shall conform to ASTM C1513. Structural sheathing shall be attached to cold-formed steel roof rafters with minimum No. 8 self-drilling tapping screws that conform to ASTM C1513. Screws for attaching structural sheathing to cold-formed steel roof framing shall have a minimum head diameter of 0.292 inch (7.4 mm) with countersunk heads and shall be installed with a minimum edge distance of 3/8 inch (9.5 mm). Gypsum board ceilings shall be attached to cold-formed steel joists with minimum No. 6 screws conforming to ASTM C954 or ASTM C1513 with a bugle-head style and shall be installed in accordance with Section R805. For all connections, screws shall extend through the steel a minimum of three exposed threads. Fasteners shall have rust-inhibitive coating suitable for the installation in which they are being used, or be manufactured from material not susceptible to corrosion.

Related Code Sections


R703.14.1.2 Wall Covering, Fastener Requirements
or substrate not less than 3 / 4 inch (19.1 mm). Where the nail fully penetrates the sheathing or nailable substrate, the end of the fastener shall extend ...
Los Angeles Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.14 Polypropylene Siding > R703.14.1 Polypropylene Siding and Accessories > R703.14.1.2 Fastener Requirements
R703.14.1.2 Wall Covering, Fastener Requirements
or substrate not less than 3 / 4 inch (19.1 mm). Where the nail fully penetrates the sheathing or nailable substrate, the end of the fastener shall extend ...
Los Angeles Residential Code > 7 Wall Covering > R703 Exterior Covering > R703.14 Polypropylene Siding > R703.14.1 Polypropylene Siding and Accessories > R703.14.1.2 Fastener Requirements
R804.2.5 Roof-Ceiling Construction, Fastening Requirements
Fasteners shall have rust-inhibitive coating suitable for the installation in which they are being used, or be manufactured from material ...
Los Angeles Residential Code > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.2 Structural Framing > R804.2.5 Fastening Requirements
R804.2.5 Roof-Ceiling Construction, Fastening Requirements
Fasteners shall have rust-inhibitive coating suitable for the installation in which they are being used, or be manufactured from material ...
Los Angeles Residential Code > 8 Roof-Ceiling Construction > R804 Cold-Formed Steel Roof Framing > R804.2 Structural Framing > R804.2.5 Fastening Requirements
2304.10.1.1 Wood, Additional Requirements
[DSA-SS and OSHPD 1, 2 & 4] Fasteners used for the attachment of exterior wall coverings shall be of hot-dipped zinc-coated galvanized steel ...
Los Angeles Building Code > 23 Wood > 2304 General Construction Requirements > 2304.10 Connectors and Fasteners > 2304.10.1 Fastener Requirements > 2304.10.1.1 Additional Requirements
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE