2304.10.5.3 Fasteners for Fire-Retardant-Treated Wood Used in Exterior Applications or Wet or Damp Locations
JUMP TO FULL CODE CHAPTER
Fasteners, including nuts and washers, for fire-retardant-treated wood used in exterior applications or wet or damp locations shall be of hot-dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Staples shall be of stainless steel. Fasteners other than nails, staples, timber rivets, wood screws and lag screws shall be permitted to be of mechanically deposited zinc-coated steel with coating weights in accordance with ASTM B695, Class 55 minimum.
Related Code Sections
2304.10.5.3 Wood, Fasteners for Fire-Retardant-Treated Wood Used in Exterior Applications or Wet or Damp Locations
Fasteners, including nuts and washers, for fire-retardant-treated wood used in exterior applications or wet or damp locations shall be of hot ...
Building Code 2018 of Illinois > 23 Wood > 2304 General Construction Requirements > 2304.10 Connectors and Fasteners > 2304.10.5 Fasteners and Connectors in Contact With Preservative-Treated and Fire-Retardant-Treated Wood > 2304.10.5.3 Fasteners for Fire-Retardant-Treated Wood Used in Exterior Applications or Wet or Damp Locations
2304.10.6.3 Wood, Fasteners for Fire-Retardant-Treated Wood Used in Exterior Applications or Wet or Damp Locations
Fasteners, including nuts and washers, for fire-retardant-treated wood used in exterior applications or wet or damp locations shall be of hot ...
Building Code 2021 of Illinois > 23 Wood > 2304 General Construction Requirements > 2304.10 Connectors and Fasteners > 2304.10.6 Fasteners and Connectors in Contact With Preservative-Treated and Fire-Retardant-Treated Wood > 2304.10.6.3 Fasteners for Fire-Retardant-Treated Wood Used in Exterior Applications or Wet or Damp Locations
2303.2.6 Wood, Exposure to Weather, Damp or Wet Locations
Where fire-retardant-treated wood is exposed to weather, or damp or wet locations, it shall be identified as "Exterior" to indicate ...
Building Code 2021 of Illinois > 23 Wood > 2303 Minimum Standards and Quality > 2303.2 Fire-Retardant-Treated Wood > 2303.2.6 Exposure to Weather, Damp or Wet Locations
2303.2.6 Wood, Exposure to Weather, Damp or Wet Locations
Where fire-retardant-treated wood is exposed to weather, or damp or wet locations, it shall be identified as "Exterior" to indicate ...
Building Code 2018 of Illinois > 23 Wood > 2303 Minimum Standards and Quality > 2303.2 Fire-Retardant-Treated Wood > 2303.2.6 Exposure to Weather, Damp or Wet Locations
2303.2 Wood, Fire-Retardant-Treated Wood
with Sections 2303.2.5 through 2303.2.8. For fire-retardant-treated wood exposed to weather, damp or wet locations, include the words "No increase ...
Building Code 2018 of Illinois > 23 Wood > 2303 Minimum Standards and Quality > 2303.2 Fire-Retardant-Treated Wood