E402.5 Fan-Failure Indicator
JUMP TO FULL CODE CHAPTER
Each soil-depressurization system shall have a failure indicator labeled with the words "RADON REDUCTION SYSTEM FAN-FAILURE INDICATOR" mounted so as to be conveniently visible to the building occupants. The fan-failure indicator may be either a visual device consisting of a light of not less than 1/5 footcandle (2 lux) at the floor level, or an alarm that produces a minimum 60 db audible signal. The indicator shall be made to operate automatically when the pressure inside any radon vent pipe fitted with an operable fan is less than 0.40-inch water column (100 pascals) lower than the air pressure inside the building.
Related Code Sections
E402.5 Florida Standard for Radon-Resistant New Commercial Construction, Fan-Failure Indicator
Each soil-depressurization system shall have a failure indicator labeled with the words "RADON REDUCTION SYSTEM FAN-FAILURE INDICATOR" mounted so ...
2017 FBC - Building, 6th edition > E Florida Standard for Radon-Resistant New Commercial Construction > E402 System Components. > E402.5 Fan-Failure Indicator
E402.5 Florida Standard for Radon-Resistant New Commercial Construction, Fan-Failure Indicator
Each soil-depressurization system shall have a failure indicator labeled with the words "RADON REDUCTION SYSTEM FAN-FAILURE INDICATOR" mounted so ...
2020 FBC - Building, 7th edition > E Florida Standard for Radon-Resistant New Commercial Construction > E401 Active Soil-Depressurization Systems > E402 System Components > E402.5 Fan-Failure Indicator
E202 Florida Standard for Radon-Resistant New Commercial Construction, Definitions.
of a pressure distribution manifold, one or more radon vents, an operating fan, and a fan-failure indicator. ADDITION. An extension or increase ...
2017 FBC - Building, 6th edition > E Florida Standard for Radon-Resistant New Commercial Construction > E202 Definitions.
E202 Florida Standard for Radon-Resistant New Commercial Construction, Definitions
of a pressure distribution manifold, one or more radon vents, an operating fan, and a fan-failure indicator. ADDITION. An extension or increase ...
2020 FBC - Building, 7th edition > E Florida Standard for Radon-Resistant New Commercial Construction > E201 Definitions > E202 Definitions
450.3.15.1 Special Detailed Requirements Based on Use and Occupancy,
Exhaust fans and other fans operating in conjunction with a negative duct system pressure shall be located at the discharge end of the system. Fans ...
2014 FBC - Building, 5th edition > 4 Special Detailed Requirements Based on Use and Occupancy > 450 Nursing Homes > 450.3 Additional Physical Plant Requirements for Nursing Homes > 450.3.15 Exhaust > 450.3.15.1