• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

909.21.4.4 Fan Capacity

2017 FBC - Building, 6th edition > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.21 Elevator Hoistway Pressurization Alternative > 909.21.4 Fan System > 909.21.4.4 Fan Capacity
JUMP TO FULL CODE CHAPTER
The supply fan shall be either adjustable with a capacity of not less than 1,000 cfm (0.4719 m3/s) per door, or that specified by a registered design professional to meet the requirements of a designed pressurization system.

Related Code Sections


909.21.4.4 Fire Protection Systems, Fan Capacity
The supply fan shall either be adjustable with a capacity of at least 1,000 cfm (0.4719 m 3 /s) per door, or that specified by a registered design ...
2014 FBC - Building, 5th edition > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.21 Elevator Hoistway Pressurization Alternative > 909.21.4 Fan System > 909.21.4.4 Fan Capacity
909.21.4.4 Fire Protection Systems, Fan Capacity
The supply fan shall be either adjustable with a capacity of not less than 1,000 cfm (0.4719 m 3 /s) per door, or that specified by a registered ...
2017 FBC - Building, 6th edition > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.21 Elevator Hoistway Pressurization Alternative > 909.21.4 Fan System > 909.21.4.4 Fan Capacity
909.21.4.4 Fire Protection Systems, Fan Capacity
The supply fan shall be either adjustable with a capacity of not less than 1,000 cfm (0.4719 m 3 /s) per door, or that specified by a registered ...
2020 FBC - Building, 7th edition > 9 Fire Protection Systems > 909 Smoke Control Systems > 909.21 Elevator Hoistway Pressurization Alternative > 909.21.4 Fan System > 909.21.4.4 Fan Capacity
504.2.6 Chimneys and Vents, Multiple Input Rate Appliances
For appliances with more than one input rate, the minimum vent capacity (FAN Min) determined from the tables shall be less than the lowest appliance ...
2014 FBC - Fuel Gas, 5th edition > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.2 Application of Single-Appliance Vent Tables 504.2(1) Through 504.2(6) > 504.2.6 Multiple Input Rate Appliances
504.2.6 Chimneys and Vents, Multiple Input Rate Appliances
For appliances with more than one input rate, the minimum vent capacity (FAN Min) determined from the tables shall be less than the lowest appliance ...
2017 FBC - Fuel Gas, 6th edition > 5 Chimneys and Vents > 504 (IFGS) Sizing of Category I Appliance Venting Systems > 504.2 Application of Single-Appliance Vent Tables 504.2(1) Through 504.2(6) > 504.2.6 Multiple Input Rate Appliances
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE