803.12 Facings or Wood Veneers Intended to Be Applied on Site Over a Wood Substrate
JUMP TO FULL CODE CHAPTER
Facings or veneers intended to be applied on site over a wood substrate shall comply with one of the following:
- The facing or veneer shall meet the criteria of Section 803.1.1.1 when tested in accordance with NFPA 286 using the product mounting system, including adhesive, as described in Section 5.9 of NFPA 286.
- The facing or veneer shall have a Class A, B or C flame spread index and smoke-developed index, based on the requirements of Table 803.13, in accordance with ASTM E84 or UL 723. Test specimen preparation and mounting shall be in accordance with ASTM E2404.
Related Code Sections
803.12 Interior Finishes, Facings or Wood Veneers Intended to Be Applied on Site Over a Wood Substrate
Facings or veneers intended to be applied on site over a wood substrate shall comply with one of the following:
The facing or veneer shall meet ...
2019 Oregon Structural Specialty Code (OSSC) > 8 Interior Finishes > 803 Wall and Ceiling Finishes > 803.12 Facings or Wood Veneers Intended to Be Applied on Site Over a Wood Substrate
1404.5 Exterior Walls, Wood Veneers
Wood veneers on exterior walls of buildings of Type I, II, III and IV construction shall be not less than 1 inch (25 mm) nominal thickness, 0.438 ...
2019 Oregon Structural Specialty Code (OSSC) > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.5 Wood Veneers
1405.5 Exterior Walls, Wood Veneers
Wood veneers on exterior walls of buildings of Type I, II, III and IV construction shall be not less than 1 inch (25 mm) nominal thickness, 0.438 ...
2014 Oregon Structural Specialty Code (OSSC) > 14 Exterior Walls > 1405 Installation of Wall Coverings > 1405.5 Wood Veneers
R703.14.1 Wall Covering, Polypropylene Siding and Accessories
Polypropylene siding shall be installed over and attached to wood structural panel ...
2017 Oregon Residential Specialty Code (ORSC) > 7 Wall Covering > R703 Exterior Covering > R703.14 Polypropylene Siding > R703.14.1 Polypropylene Siding and Accessories
R606.14.1 Wall Construction, Anchored Veneer
Anchored masonry veneer installed over a backing of wood or cold-formed steel shall meet the requirements of Section R703.8 ...
2017 Oregon Residential Specialty Code (ORSC) > 6 Wall Construction > R606 General Masonry Construction > R606.14 Anchored and Adhered Masonry Veneer > R606.14.1 Anchored Veneer