• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R610.3.2 Facing

Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 6 Wall Construction > R610 Structural Insulated Panel Wall Construction > R610.3 Materials > R610.3.2 Facing
JUMP TO FULL CODE CHAPTER
Facing materials for SIPs shall be wood structural panels conforming to DOC PS 1 or DOC PS 2, each having a minimum nominal thickness of 7/16 inch (11 mm) and shall meet the additional minimum properties specified in Table R610.3.2. Facing shall be identified by a grade mark or certificate of inspection issued by an approved agency.

TABLE R610.3.2
MINIMUM PROPERTIESa FOR ORIENTED STRAND BOARD FACER MATERIAL IN SIP WALLS
THICKNESS
(in.)
PRODUCT FLATWISE STIFFNESSb
(lbf-in2/ft)
FLATWISE STRENGTHc
(lbf-in/ft)
TENSIONc
(lbf/ft)
DENSITYd
(pcf)
Along Across Along Across Along Across
7/16 Sheathing 55,600 16,500 1,040 460 7,450 5,800 34

For SI: 1 inch = 25.4 mm, 1 lbf-in2/ft = 9.415 × 10-6 kPa/m, 1 lbf-in/ft = 3.707 × 10-4 kN/m, 1 lbf/ft = 0.0146 N/mm, 1 pound per cubic foot = 16.018 kg/m3.
  1. Values listed in Table R610.3.2 are qualification test values and are not to be used for design purposes.
  2. Mean test value shall be in accordance with Section 7.6 of DOC PS 2.
  3. Characteristic test value (5th percent with 75% confidence).
  4. Density shall be based on oven-dry weight and oven-dry volume.

Related Code Sections


720.2.1 Fire and Smoke Protection Features, Facings
limitations do not apply to facings, coverings, and layers of reflective foil insulation that are installed behind and in substantial contact ...
Building Code of the Texas Industrialized Housing and Buildings Program > 7 Fire and Smoke Protection Features > 720 Thermal- And Sound-Insulating Materials > 720.2 Concealed Installation > 720.2.1 Facings
R610.3.2 Wall Construction, Facing
Facing materials for SIPs shall be wood structural panels conforming to DOC PS 1 or DOC PS 2, each having a minimum nominal thickness of 7 / 16 ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 6 Wall Construction > R610 Structural Insulated Panel Wall Construction > R610.3 Materials > R610.3.2 Facing
403.12.5 Gas Piping Installations, Raised Face
Raised face flanges shall not be joined to flat faced cast-iron, ductile-iron or nonferrous material flanges ...
Fuel Gas Code of the Texas Industrialized Housing and Buildings Program > 4 Gas Piping Installations > 403 (IFGS) Piping Materials > 403.12 Flanges > 403.12.5 Raised Face
408.8.3 Special Detailed Requirements Based on Use and Occupancy, Openings in Room Face
The aggregate area of openings in a solid sleeping room face in Occupancy Conditions 2, 3, 4 and 5 shall not exceed 120 square inches (0.77 m 2 ...
Building Code of the Texas Industrialized Housing and Buildings Program > 4 Special Detailed Requirements Based on Use and Occupancy > 408 Group I-3 > 408.8 Subdivision of Resident Housing Areas > 408.8.3 Openings in Room Face
502.7.3.3.1 Exhaust Systems, Open Face or Open Front Spray Booth
For spray application operations conducted in an open face or open front spray booth, the ventilation system shall be designed, installed ...
Mechanical Code of the Texas Industrialized Housing and Buildings Program > 5 Exhaust Systems > 502 Required Systems > 502.7 Application of Flammable Finishes > 502.7.3 Flammable Vapor Areas > 502.7.3.3 Air Velocity > 502.7.3.3.1 Open Face or Open Front Spray Booth
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE