5001.6 Facility Closure
JUMP TO FULL CODE CHAPTER
Facilities that are temporarily out of service shall continue to maintain a permit and be monitored and inspected.
Facilities for which a permit is not kept current or is not monitored and inspected on a regular basis shall be deemed to be permanently out of service and shall be closed in an approved manner. Where required by the fire code official, permittees shall apply for approval to close permanently storage, use or handling facilities. The fire code official is authorized to require that such application be accompanied by an approved facility closure plan in accordance with Section 5001.6.3.
Where a facility closure plan is required in accordance with Section 5001.5 to terminate storage, dispensing, handling or use of hazardous materials, it shall be submitted to the fire code official not less than 30 days prior to facility closure. The plan shall demonstrate that hazardous materials that are stored, dispensed, handled or used in the facility will be transported, disposed of or reused in a manner that eliminates the need for further maintenance and any threat to public health and safety.
Related Code Sections
2701.6 Hazardous Materials-General Provisions, Facility Closure
When a facility closure plan is required in accordance with Section 2701.5 to terminate storage, dispensing, handling or use of hazardous materials ...
2010 Fire Code of NY > 27 Hazardous Materials-General Provisions > 2701 General > 2701.6 Facility Closure
5001.6 Hazardous Materials—General Provisions, Facility Closure
fire code official is authorized to require that such application be accompanied by an approved facility closure plan in accordance with Section ...
Fire Code 2015 of New York State > 50 Hazardous Materials—General Provisions > 5001 General > 5001.6 Facility Closure
5001.6 Hazardous Materials — General Provisions, Facility Closure
fire code official is authorized to require that such application be accompanied by an approved facility closure plan in accordance with Section ...
2020 Fire Code of NYS > 50 Hazardous Materials — General Provisions > 5001 General > 5001.6 Facility Closure
407.7 Emergency Planning and Preparedness, Facility Closure Plans
The permit holder or applicant shall submit to the fire code official a facility closure plan in accordance with Section 5001.6.3 to terminate ...
Fire Code 2015 of New York State > 4 Emergency Planning and Preparedness > 407 Hazard Communication > 407.7 Facility Closure Plans
407.7 Emergency Planning and Preparedness, Facility Closure Plans
A facility closure plan in accordance with Section 2701.6.3 to terminate storage, dispensing, handling or use of hazardous materials shall ...
2010 Fire Code of NY > 4 Emergency Planning and Preparedness > 407 Hazard Communication > 407.7 Facility Closure Plans