// CODE SNIPPET
E4001.11.1 Faceplate Grounding
JUMP TO FULL CODE CHAPTER
Snap switches, including dimmer and similar control switches, shall be connected to an equipment grounding conductor and shall provide a means to connect metal faceplates to the equipment grounding conductor, whether or not a metal faceplate is installed. Snap switches shall be considered to be part of an effective ground-fault current path if either of the following conditions is met:
- The switch is mounted with metal screws to a metal box or metal cover that is connected to an equipment grounding conductor or to a nonmetallic box with integral means for connecting to an equipment grounding conductor.
- An equipment grounding conductor or equipment bonding jumper is connected to an equipment grounding termination of the snap switch.
Exceptions:
- Where a means to connect to an equipment grounding conductor does not exist within the snap-switch enclosure or where the wiring method does not include or provide an equipment grounding conductor, a snap switch without a grounding connection to an equipment grounding conductor shall be permitted for replacement purposes only. A snap switch wired under the provisions of this exception and located within 8 feet (2438 mm) vertically or 5 feet (1524 mm) horizontally of ground or exposed grounded metal objects, shall be provided with a faceplate of nonconducting noncombustible material with nonmetallic attachment screws, except where the switch-mounting strap or yoke is nonmetallic or the circuit is protected by a ground-fault circuit interrupter.
- Listed kits or listed assemblies shall not be required to be connected to an equipment grounding conductor if all of the following conditions apply:
- The device is provided with a nonmetallic faceplate that cannot be installed on any other type of device.
- The device does not have mounting means to accept other configurations of faceplates.
- The device is equipped with a nonmetallic yoke.
- All parts of the device that are accessible after installation of the faceplate are manufactured of nonmetallic materials.
- Connection to an equipment grounding conductor shall not be required for snap switches that have an integral nonmetallic enclosure complying with Section E3905.13.
Related Code Sections
E4001.11.1 Devices and Luminaires, Faceplate Grounding
to connect metal faceplates to the equipment grounding conductor, whether or not a metal faceplate is installed. Snap switches shall be considered ...
2012 Virginia Residential Code > 40 Devices and Luminaires > E4001 Switches > E4001.11 Snap Switch Faceplates > E4001.11.1 Faceplate Grounding
E4001.11.1 Devices and Luminaires, Faceplate Grounding
to connect metal faceplates to the equipment grounding conductor, whether or not a metal faceplate is installed. Snap switches shall be considered ...
2015 Virginia Residential Code > 40 Devices and Luminaires > E4001 Switches > E4001.11 Snap Switch Faceplates > E4001.11.1 Faceplate Grounding
605.2 Mechanical and Electrical Requirements, Receptacles
bathroom receptacle outlet shall have ground fault circuit interrupter protection. All receptacle outlets shall have the appropriate faceplate cover ...
2012 Virginia Maintenance Code (USBC, Part III) > 6 Mechanical and Electrical Requirements > 605 Electrical Equipment > 605.2 Receptacles