• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§28-303.2.2 External Inspection Required

NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 303 Periodic Boiler Inspections > §28-303.2 Annual Inspections > §28-303.2.2 External Inspection Required
JUMP TO FULL CODE CHAPTER
All high and low pressure boilers shall have an annual external inspection performed in accordance with section 204 of New York state labor law and the rules of the department. Such inspection shall include chimney connectors.

Related Code Sections


§28-303.2.2 Maintenance of Buildings, External Inspection Required
All high and low pressure boilers shall have an annual external inspection performed in accordance with section 204 of New York state labor law ...
NYC General Admin. Provisions 2014 > 3 Maintenance of Buildings > 303 Periodic Boiler Inspections > §28-303.2 Annual Inspections > §28-303.2.2 External Inspection Required
§28-303.2.2 Maintenance of Buildings, External Inspection Required
All high and low pressure boilers shall have an annual external inspection performed in accordance with section 204 of New York state labor law ...
NYC General Admin. Provisions 2022 > 3 Maintenance of Buildings > 303 Periodic Boiler Inspections > §28-303.2 Annual Inspections > §28-303.2.2 External Inspection Required
8.10.4.1.1 General Requirements, External Inspection and Tests
(a) General Fire Protection Requirements (Items 7.1 and 9.1) (1) The protection of floor and wall openings shall be inspected to determine ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.10 Acceptance Inspections and Tests > 8.10.4 Acceptance Inspection and Tests of Escalators and Moving Walks > 8.10.4.1 Inspection and Test Requirements for New Installations > 8.10.4.1.1 External Inspection and Tests
8.3.5.3.3 General Requirements, External Leakage
The hydraulic pressure shall be maintained at twice the component rated pressure for a period of 10 min to establish the rate of leakage. The rate ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.3 Engineering Tests, Type Tests, and Certification > 8.3.5 Type Tests for Hydraulic Control Valves > 8.3.5.3 Test Procedure > 8.3.5.3.3 External Leakage
3305.3.2.4 Safeguards During Construction or Demolition, External Loads
Braces and shores shall be designed to resist all external loads, including, but not limited to, wind, cable tensions, inclined supports, dumping ...
NYC Building Code 2022 > 33 Safeguards During Construction or Demolition > 3305 Material Placement and Installation > 3305.3 Concrete Formwork > 3305.3.2 Design of Concrete Formwork > 3305.3.2.4 External Loads
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING