• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1709.5.2 Exterior Windows and Door Assemblies Not Provided for in Section 1709.5.1

Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.5 Exterior Window and Door Assemblies > 1709.5.2 Exterior Windows and Door Assemblies Not Provided for in Section 1709.5.1
JUMP TO FULL CODE CHAPTER
Exterior window and door assemblies shall be tested in accordance with ASTM E330. Structural performance of garage doors and rolling doors shall be determined in accordance with either ASTM E330 or ANSI/DASMA 108, and shall meet the acceptance criteria of ANSI/DASMA 108. Exterior window and door assemblies containing glass shall comply with Section 2403. The design pressure for testing shall be calculated in accordance with Chapter 16. Each assembly shall be tested for 10 seconds at a load equal to 1.5 times the design pressure.

Related Code Sections


1709.5.2 Special Inspections and Tests, Exterior Windows and Door Assemblies Not Provided for in Section 1709.5.1
Exterior window and door assemblies shall be tested in accordance with ASTM E330. Structural performance of garage doors and rolling doors shall ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.5 Exterior Window and Door Assemblies > 1709.5.2 Exterior Windows and Door Assemblies Not Provided for in Section 1709.5.1
1709.5.2 Special Inspections and Tests, Exterior Windows and Door Assemblies Not Provided for in Section 1709.5.1
Exterior window and door assemblies shall be tested in accordance with E330. Exterior window and door assemblies containing glass shall comply ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests > 1709.5 Exterior Window and Door Assemblies > 1709.5.2 Exterior Windows and Door Assemblies Not Provided for in Section 1709.5.1
Section 1709 Special Inspections and Tests, Preconstruction Load Tests
windows and doors in buildings shall be determined in accordance with Section 1709.5.1 or 1709.5.2. For exterior windows and doors tested in accordance ...
Building Code 2021 of Illinois > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests
Section 1709 Special Inspections and Tests, Preconstruction Load Tests
and doors in buildings shall be determined in accordance with Section 1709.5.1 or 1709.5.2. For exterior windows and doors tested in accordance with Sections ...
Building Code 2018 of Illinois > 17 Special Inspections and Tests > 1709 Preconstruction Load Tests
1404.13 Exterior Walls, Exterior Windows and Doors
Windows and doors installed in exterior walls shall conform to the testing and performance requirements of Section 1709.5 ...
Building Code 2021 of Illinois > 14 Exterior Walls > 1404 Installation of Wall Coverings > 1404.13 Exterior Windows and Doors
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING