1012.6.1 Exterior Wall Rating for Change of Occupancy Classification to a Higher Hazard Category
JUMP TO FULL CODE CHAPTER
When a change of occupancy classification is made to a higher hazard category as shown in Table 1012.6, exterior walls shall have fire resistance and exterior opening protectives as required by the International Building Code.
Exception: A 2-hour fire-resistance rating shall be allowed where the building does not exceed three stories in height and is classified as one of the following groups: A-2 and A-3 with an occupant load of less than 300, B, F, M or S.
Related Code Sections
1012.6.1 Change of Occupancy, Exterior Wall Rating for Change of Occupancy Classification to a Higher Hazard Category
When a change of occupancy classification is made to a higher hazard category as shown in Table 1012.6, exterior walls shall have fire resistance ...
2015 Michigan Rehabilitation Code > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.6 Exterior Wall Fire-Resistance Ratings > 1012.6.1 Exterior Wall Rating for Change of Occupancy Classification to a Higher Hazard Category
1012.4.1 Change of Occupancy, Means of Egress for Change to Higher Hazard Category
When a change of occupancy classification is made to a higher hazard category (lower number) as shown in Table 1012.4, the means of egress shall ...
2015 Michigan Rehabilitation Code > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.4 Means of Egress, General > 1012.4.1 Means of Egress for Change to Higher Hazard Category
1012.5.1.1 Change of Occupancy, Fire Wall Alternative
Building Code. The fire-resistance rating of the fire barriers and horizontal assemblies shall be not less than that specified for fire walls ...
2015 Michigan Rehabilitation Code > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.5 Heights and Areas > 1012.5.1 Height and Area for Change to Higher Hazard Category > 1012.5.1.1 Fire Wall Alternative
1012.7 Change of Occupancy, Enclosure of Vertical Shafts
of occupancy classification is made to a higher hazard category as shown in Table 1012.4, interior stairways shall be enclosed as required ...
2015 Michigan Rehabilitation Code > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.7 Enclosure of Vertical Shafts
1012.4 Change of Occupancy, Means of Egress, General
EGRESS HAZARD CATEGORIES
RELATIVE HAZARD
OCCUPANCY CLASSIFICATIONS
1 (Highest Hazard)
H
2
I-2 ...
2015 Michigan Rehabilitation Code > 10 Change of Occupancy > 1012 Change of Occupancy Classification > 1012.4 Means of Egress, General