• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

C405.2.6.4 Exterior Time-Switch Control Function

Energy Conservation Code 2018 of Nevada > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.6 Exterior Lighting Controls > C405.2.6.4 Exterior Time-Switch Control Function
JUMP TO FULL CODE CHAPTER

Time-switch controls for exterior lighting shall comply with the following:

  1. They shall have a clock capable of being programmed for not fewer than 7 days.
  2. They shall be capable of being set for seven different day types per week.
  3. They shall incorporate an automatic holiday setback feature.
  4. They shall have program backup capabilities that prevent the loss of program and time settings for a period of not less than 10 hours in the event that power is interrupted.

Related Code Sections


C405.2.6.4 [CE] Commercial Energy Efficiency, Exterior Time-Switch Control Function
Time-switch controls for exterior lighting shall comply with the following: They shall have a clock capable of being programmed for not fewer than ...
Energy Conservation Code 2018 of Nevada > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems > C405.2 Lighting Controls (Mandatory) > C405.2.6 Exterior Lighting Controls > C405.2.6.4 Exterior Time-Switch Control Function
C408.3.1.2 [CE] Commercial Energy Efficiency, Time-Switch Controls
Where time-switch controls are provided, the following procedures shall be performed: Confirm that the time-switch control is programmed ...
Energy Conservation Code 2018 of Nevada > 4 [CE] Commercial Energy Efficiency > C408 Maintenance Information and System Commissioning > C408.3 Functional Testing of Lighting Controls > C408.3.1 Functional Testing > C408.3.1.2 Time-Switch Controls
C405.2.4 [CE] Commercial Energy Efficiency, Exterior Lighting Controls
Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch, or an astronomical ...
Energy Conservation Code 2012 of Nevada > 4 [CE] Commercial Energy Efficiency > C405 Electrical Power and Lighting Systems (Mandatory) > C405.2 Lighting Controls (Mandatory) > C405.2.4 Exterior Lighting Controls
R403.10.2 [RE] Residential Energy Efficiency, Time Switches
Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump ...
Energy Conservation Code 2018 of Nevada > 4 [RE] Residential Energy Efficiency > R403 Systems > R403.10 Pools and Permanent Spa Energy Consumption (Mandatory) > R403.10.2 Time Switches
C404.9.2 [CE] Commercial Energy Efficiency, Time Switches
Time switches or other control methods that can automatically turn off and on heaters and pump motors according to a preset schedule shall ...
Energy Conservation Code 2018 of Nevada > 4 [CE] Commercial Energy Efficiency > C404 Service Water Heating (Mandatory) > C404.9 Energy Consumption of Pools and Permanent Spas (Mandatory) > C404.9.2 Time Switches
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE