All exterior structural steel members exposed to weather shall have a minimum thickness of metal of 0.23 inches (5.8 mm).
Exceptions:
  1. When an approved type of atmospheric corrosion- resistant steel is used.
  2. Exposed surfaces are zinc coated with a minimum weight of coating of approximately 0.6 ounces per square foot (0.00156 kg/m2) of exposed surface and covered with a protective coating as required by Section 2203.2.
  3. Exposed surfaces are protected by other means approved by the commissioner.
  4. Temporary construction installations that will be in place for a period of 1 year or less, provided that all surfaces which are exposed to the weather shall have a protective coating as required by Section 2203.2.
  5. Joists or purlins that are exposed to the weather but which do not support more than 200 square feet (19 m2) of floor or roof area, and which have a protective coating as required by Section 2203.2.
Upcodes Diagrams

Related Code Sections

2211.2 Steel, Exterior Members
All exterior structural steel members exposed to weather shall have a minimum thickness of metal of 0.23 inches (5.8 mm). Exceptions: When ...
2212.1 Steel, Exterior Members
All exterior structural steel members exposed to weather shall have a minimum thickness of metal of 0.23 inches (5.8 mm).   Exceptions ...
2212.2 Steel, Exterior Members
All exterior structural steel members exposed to weather shall have a minimum thickness of metal of 0.23 inches (5.8 mm). Exceptions: When ...
602.4.3 Types of Construction, Exterior Structural Members
Where a horizontal separation of 20 feet (6096 mm) or more is provided, wood columns and arches conforming to heavy timber sizes in accordance ...
602.4.7 Types of Construction, Exterior Structural Members
Where a horizontal separation of 20 feet (6096 mm) or more is provided, wood columns and arches conforming to heavy timber sizes shall be permitted ...