R703.9 Exterior Insulation Finish Systems, General
JUMP TO FULL CODE CHAPTER
All Exterior Insulation Finish Systems (EIFS) shall be installed in accordance with the manufacturer's installation instructions and the requirements of this section. Decorative trim shall not be face nailed through the EIFS. The EIFS shall terminate not less than 6 inches (152 mm) above the finished ground level.
All EIFS shall have a water-resistive barrier applied between the underlying water-sensitive building components and the exterior insulation, and a means of draining water to the exterior of the veneer. A water-resistive barrier shall be compliant with ASTM D 226 Type I asphalt saturated felt or equivalent, shall be applied horizontally with the upper layer lapped over the lower layer not less than 2 inches (51 mm), and shall have all vertical joints lapped not less than 6 inches (152 mm).
Flashing of EIFS shall be provided in accordance with the requirements of Section R703.8.
Related Code Sections
R703.9 Wall Covering, Exterior Insulation Finish Systems, General
All Exterior Insulation Finish Systems (EIFS) shall be installed in accordance with the manufacturer's installation instructions and the requirements ...
2010 Residential Code of NY > 7 Wall Covering > R703 Exterior Covering > R703.9 Exterior Insulation Finish Systems, General
1407.1 Exterior Walls, General
The provisions of this section shall govern the materials, construction and quality of exterior insulation and finish systems (EIFS) for use ...
2020 Building Code of New York State > 14 Exterior Walls > 1407 Exterior Insulation and Finish Systems (EIFS) > 1407.1 General
1408.1 Exterior Walls, General
The provisions of this section shall govern the materials, construction and quality of exterior insulation and finish systems (EIFS) for use ...
Building Code 2015 of New York State > 14 Exterior Walls > 1408 Exterior Insulation and Finish Systems (EIFS) > 1408.1 General
1402.1 Exterior Walls, General
, siding, exterior insulation and finish systems, architectural trim and embellishments such as cornices, soffits, facias, gutters and leaders. EXTERIOR ...
1403.11 Exterior Walls, Exterior Insulation and Finish Systems
Exterior insulation and finish systems (EIFS) and exterior insulation and finish systems (EIFS) with drainage shall comply with Section 1407 ...
2020 Building Code of New York State > 14 Exterior Walls > 1403 Materials > 1403.11 Exterior Insulation and Finish Systems