Exit access travel distances specified in Table 1017.2 shall be increased up to an additional 100 feet (30 480 mm) provided that the last portion of the exit access leading to the exit occurs on an exterior egress balcony constructed in accordance with Section 1021. The length of such balcony shall be not less than the amount of the increase taken.

Related Code Sections

1017.2.1 Means of Egress, Exterior Egress Balcony Increase
of the exit access leading to the exit occurs on an exterior egress balcony constructed in accordance with Section 1021. The length of such balcony shall ...
1017.2.1 Means of Egress, Exterior Egress Balcony Increase
of the exit access leading to the exit occurs on an exterior egress balcony constructed in accordance with Section 1021. The length of such balcony shall ...
1021.2 Means of Egress, Wall Separation
Exterior egress balconies shall be separated from the interior of the building by walls and opening protectives as required for corridors. Exception ...