2111.14 Exterior Air
JUMP TO FULL CODE CHAPTER
Factory-built or masonry fireplaces covered in this section shall be equipped with an exterior air supply to ensure proper fuel combustion unless the room is mechanically ventilated and controlled so that the indoor pressure is neutral or positive.
Exterior combustion air ducts for factory-built fireplaces shall be listed components of the fireplace, and installed according to the fireplace manufacturer's instructions.
Listed combustion air ducts for masonry fireplaces shall be installed according to the terms of their listing and manufacturer's instructions.
The exterior air intake shall be capable of providing all combustion air from the exterior of the dwelling. The exterior air intake shall not be located within a garage, attic, basement or crawl space of the dwelling nor shall the air intake be located at an elevation higher than the firebox. The exterior air intake shall be covered with a corrosion-resistant screen of 1/4-inch (6.4 mm) mesh.
Unlisted combustion air ducts shall be installed with a minimum 1-inch (25 mm) clearance to combustibles for all parts of the duct within 5 feet (1524 mm) of the duct outlet.
The combustion air passageway shall be not less than 6 square inches (3870 mm2) and not more than 55 square inches (0.035 m2), except that combustion air systems for listed fireplaces or for fireplaces tested for emissions shall be constructed according to the fireplace manufacturer's instructions.
The exterior air outlet is permitted to be located in the back or sides of the firebox chamber or within 24 inches (610 mm) of the firebox opening on or near the floor. The outlet shall be closable and designed to prevent burning material from dropping into concealed combustible spaces.
Related Code Sections
2111.14 Masonry, Exterior Air
Factory-built or masonry fireplaces covered in this section shall be equipped with an exterior air supply to ensure proper fuel combustion unless ...
2111.14 Masonry, Exterior Air
Factory-built or masonry fireplaces covered in this section shall be equipped with an exterior air supply to ensure proper fuel combustion unless ...
2111.14.2 Masonry, Masonry Fireplaces
Listed combustion air ducts for masonry fireplaces shall be installed according to the terms of their listing and manufacturer's instructions ...
Building Code 2018 of Illinois > 21 Masonry > 2111 Masonry Fireplaces > 2111.14 Exterior Air > 2111.14.2 Masonry Fireplaces
2111.14.4 Masonry, Clearance
Unlisted combustion air ducts shall be installed with a minimum 1-inch (25 mm) clearance to combustibles for all parts of the duct within 5 feet ...
Building Code 2021 of Illinois > 21 Masonry > 2111 Masonry Fireplaces > 2111.14 Exterior Air > 2111.14.4 Clearance
2111.14.4 Masonry, Clearance
Unlisted combustion air ducts shall be installed with a minimum 1-inch (25 mm) clearance to combustibles for all parts of the duct within 5 feet ...
Building Code 2018 of Illinois > 21 Masonry > 2111 Masonry Fireplaces > 2111.14 Exterior Air > 2111.14.4 Clearance