Section 1110A Exterior Accessible Routes

Go To Full Code Chapter
1110A.1 General
When a building or portion of a building is required to be accessible or adaptable, an accessible route shall be provided to all portions of the building, accessible building entrances and between the building and the public way. The accessible route shall be the most practical direct route and to the maximum extent feasible, coincide with the route for the general public and building residents.
Exterior accessible routes shall be provided as follows:
  1. At least one accessible route within the boundary of the site shall be provided from public transportation stops, accessible parking and accessible passenger loading and unloading zones, and public streets or sidewalks to the accessible building entrance they serve. Where more than one route of travel is provided, all routes shall be accessible.
  2. At least one accessible route shall connect accessible buildings, facilities, elements and spaces that are on the same site. Accessible routes shall be provided between accessible buildings and accessible site facilities when more than one building or facility is located on a site.
  3. At least one accessible route shall connect accessible building or facility entrances with all accessible spaces, elements and covered multifamily dwelling units.
  4. An accessible route shall connect at least one accessible entrance of each covered multifamily dwelling unit with exterior spaces and facilities that serve the dwelling unit.
  5. Where elevators are provided for vertical access, all elevators shall be accessible. See Section 1124A.
1110A.2 Signs
At every primary public entrance and at every major junction where the accessible route diverges from the circulation path along or leading to an accessible route, entrance or facility, there shall be a sign displaying the "International Symbol of Accessibility." Signs shall indicate the direction to accessible building entrances and facilities and shall comply with the requirements found in Section 1143A.
1110A.3 Floor and Ground Surfaces
Floor and ground surfaces shall be stable, firm and slip resistant. If carpet or carpet tile is used in a common-use area or public-use area on a ground or floor surface, it shall have firm backing or no backing. Carpet or carpet tile shall have a level loop, textured loop, level cut pile or level cut/uncut pile texture. The maximum pile height shall be 1/2 inch (12.7 mm). Exposed edges of carpet shall be fastened to floor surfaces and have trim along the entire length of the exposed edge. Carpet edge trim shall comply with Section 1111A requirements for changes in level.
1110A.3.1 Recessed Doormats
Recessed doormats shall be adequately anchored to prevent interference with wheelchair traffic.
1110A.4 Exterior Accessible Routes Over 200 Feet
Exterior accessible routes that exceed 200 feet (60 960 mm) in length shall comply with Section 1138A.1.2. (See Figure 11A-1L)

Related Code Sections

Section 1110A Housing Accessibility, Exterior Accessible Routes
and to the maximum extent feasible, coincide with the route for the general public and building residents. Exterior accessible routes shall be provided ...
Section 1110A Housing Accessibility, Exterior Accessible Routes
and to the maximum extent feasible, coincide with the route for the general public and building residents. Exterior accessible routes shall be provided ...
Section 1110A Housing Accessibility, Exterior Accessible Routes
and to the maximum extent feasible, coincide with the route for the general public and building residents. Exterior accessible routes shall be provided ...
1110A.4 Housing Accessibility, Exterior Accessible Routes Over 200 Feet
Exterior accessible routes that exceed 200 feet (60 960 mm) in length shall comply with Section 1138A.1.2. (See Figure 11A-1L) ...
1110A.2 Housing Accessibility, Signs
At every primary public entrance and at every major junction where the accessible route diverges from the circulation path along or leading ...