606.2.2.3 Extent of Repair for Noncompliant Buildings
JUMP TO FULL CODE CHAPTER
If the evaluation does not establish that the building in its predamage condition complies with the provisions of Section 606.2.2.1, then the building shall be rehabilitated to comply with the provisions of this section. The wind loads for the repair and rehabilitation shall be those required by the building code in effect at the time of original construction, unless the damage was caused by wind, in which case the wind loads shall be in accordance with the International Building Code. The seismic loads for this rehabilitation design shall be those required by the building code in effect at the time of original construction, but not less than the reduced International Building Code-level seismic forces.
Related Code Sections
404.2.3 Prescriptive Compliance Method, Extent of Repair for Noncompliant Buildings
for the repair shall be as required by the building code in effect at the time of original construction, unless the damage was caused by wind, in which ...
Existing Building Code of the Texas Industrialized Housing and Buildings Program > 4 Prescriptive Compliance Method > 404 Repairs > 404.2 Substantial Structural Damage to Vertical Elements of the Lateral Force-Resisting System > 404.2.3 Extent of Repair for Noncompliant Buildings
606.2.2.3 Repairs, Extent of Repair for Noncompliant Buildings
, then the building shall be rehabilitated to comply with the provisions of this section. The wind loads for the repair and rehabilitation shall be those required ...
Existing Building Code of the Texas Industrialized Housing and Buildings Program > 6 Repairs > 606 Structural > 606.2 Repairs to Damaged Buildings > 606.2.2 Substantial Structural Damage to Vertical Elements of the Lateral Force-Resisting System > 606.2.2.3 Extent of Repair for Noncompliant Buildings
Section 404 Prescriptive Compliance Method, Repairs
Buildings and structures, and parts thereof, shall be repaired in compliance with Sections 401.2 and 404. Work on nondamaged components ...
Existing Building Code of the Texas Industrialized Housing and Buildings Program > 4 Prescriptive Compliance Method > 404 Repairs
606.1 Repairs, General
Structural repairs shall be in compliance with this section and Section 601.2. Regardless of the extent of structural or nonstructural damage ...
Existing Building Code of the Texas Industrialized Housing and Buildings Program > 6 Repairs > 606 Structural > 606.1 General