// CODE SNIPPET
J404.3.2.1.1 Extent of Repair
JUMP TO FULL CODE CHAPTER
The evaluation and analysis shall demonstrate that the building, once repaired, complies with the applicable wind and seismic provisions of this code.
Related Code Sections
J404.3.2.1.1 Existing Buildings and Structures, Extent of Repair
The evaluation and analysis shall demonstrate that the building, once repaired, complies with the applicable wind and seismic provisions of this code ...
2010 Residential Code of NY > J Existing Buildings and Structures > J404 Structural > J404.3 Damaged Buildings > J404.3.2 Substantial Structural Damage > J404.3.2.1 Engineering Evaluation and Analysis > J404.3.2.1.1 Extent of Repair
404.2.2 Prescriptive Compliance Method, Extent of Repair for Compliant Buildings
If the evaluation establishes compliance of the predamage building in accordance with Section 404.2.1, then repairs shall be permitted that restore ...
Existing Building Code 2015 of New York State > 4 Prescriptive Compliance Method > 404 Repairs > 404.2 Substantial Structural Damage to Vertical Elements of the Lateral Force-Resisting System > 404.2.2 Extent of Repair for Compliant Buildings
405.2.3.2 Repairs, Extent of Repair for Compliant Buildings
If the evaluation establishes that the building in its predamage condition complies with the provisions of Section 405.2.3.1, then the damaged ...
2020 Existing Building Code of NYS > 4 Repairs > 405 Structural > 405.2 Repairs to Damaged Buildings > 405.2.3 Substantial Structural Damage to Vertical Elements of the Lateral Force-Resisting System > 405.2.3.2 Extent of Repair for Compliant Buildings
506.2.2.2 Repairs, Extent of Repair for Compliant Buildings
If the evaluation establishes compliance of the predamaged building in accordance with Section 506.2.2.1, then repairs shall be permitted ...
2010 Existing Building Code of NY > 5 Repairs > 506 Structural > 506.2 Repairs to Damaged Buildings > 506.2.2 Substantial Structural Damage to Vertical Elements of the Lateral-Force-Resisting System > 506.2.2.2 Extent of Repair for Compliant Buildings
606.2.2.2 Repairs, Extent of Repair for Compliant Buildings
If the evaluation establishes that the building in its predamage condition complies with the provisions of Section 606.2.2.1, then the damaged ...
Existing Building Code 2015 of New York State > 6 Repairs > 606 Structural > 606.2 Repairs to Damaged Buildings > 606.2.2 Substantial Structural Damage to Vertical Elements of the Lateral Force-Resisting System > 606.2.2.2 Extent of Repair for Compliant Buildings