P3103.6 Extension Through the Wall
JUMP TO FULL CODE CHAPTER
Vent terminals extending through the wall shall terminate not less than 10 feet (3048 mm) from the lot line and 10 feet (3048 mm) above the highest adjacent grade within 10 feet (3048 mm) horizontally of the vent terminal. Vent terminals shall not terminate under the overhang of a structure with soffit vents. Side wall vent terminals shall be protected to prevent birds or rodents from entering or blocking the vent opening.
Related Code Sections
P3103.6 Vents, Extension Through the Wall
Vent terminals extending through the wall shall terminate not less than 10 feet (3048 mm) from the lot line and 10 feet (3048 mm) above the highest ...
Residential Code 2012 of South Holland > 31 Vents > P3103 Vent Terminals > P3103.6 Extension Through the Wall
388.10 Wiring Methods and Materials, Uses Permitted
Extension through walls and floors shall be permitted. Surface nonmetallic raceway shall be permitted to pass transversely through dry walls, dry ...
National Electrical Code 2014 of South Holland > 3 Wiring Methods and Materials > 388 Surface Nonmetallic Raceways > 388.10 Uses Permitted
386.10 Wiring Methods and Materials, Uses Permitted
) locations as permitted in 501.10(B)(3). Under raised floors, as permitted in 645.5(E)(2). Extension through walls and floors. Surface metal ...
National Electrical Code 2014 of South Holland > 3 Wiring Methods and Materials > 386 Surface Metal Raceways > 386.10 Uses Permitted
P3103.2 Vents, Frost Closure
Where the 97.5-percent value for outside design temperature is 0°F (-18°C) or less, vent extensions through a roof or wall shall be not less than 3 ...
376.10 Wiring Methods and Materials, Uses Permitted
transversely through walls, if the length passing through the wall is unbroken. Access to the conductors shall be maintained on both sides of the wall ...
National Electrical Code 2014 of South Holland > 3 Wiring Methods and Materials > 376 Metal Wireways > 376.10 Uses Permitted