The floor surface of ramp runs and ramp landings shall extend 12 inches (305 mm) minimum beyond the inside face of a railing complying with Section 505.
FIGURE 405.9.1
EXTENDED FLOOR SURFACE
Upcodes Diagrams

Related Code Sections

405.9.1 Accessible Routes, Extended Floor Surface
The floor surface of ramp runs and ramp landings shall extend 12 inches (305 mm) minimum beyond the inside face of a railing complying with Section ...
1012.10.2 Means of Egress, Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying ...
1012.10.2 Means of Egress, Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying ...
405.9.1 Accessible Routes, Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying ...